Document Detail

Stanford University Network for Diagnosis of Retinopathy of Prematurity (SUNDROP): Four-years of Screening with Telemedicine.
MedLine Citation:
PMID:  23330739     Owner:  NLM     Status:  Publisher    
Abstract Purpose: To report the four-year experience of the Stanford University Network for Diagnosis of Retinopathy of Prematurity (SUNDROP) telemedicine initiative, which was developed to reduce the risk of blindness from retinopathy of prematurity (ROP). Materials and methods: A retrospective analysis of the SUNDROP archival data between 12/1/2005 and 11/30/2009. A total of 410 consecutively enrolled infants meeting ROP screening criteria had nurse-obtained fundoscopic images evaluated remotely by an ROP specialist. Every infant then received at least one dilated bedside binocular indirect ophthalmoscope (BIO) examination within one week of discharge. All infants were then followed with both telemedicine images and bedside evaluation in clinic according to recommended screening timelines. Primary outcomes were treatment-warranted ROP (TW-ROP), defined as Early Treatment of ROP Type 1, and adverse anatomical outcomes. Results: The SUNDROP telemedicine screening initiative has not missed any TW-ROP in its four-year evaluation period. A total of 410 infants (820 eyes) were imaged, resulting in 1486 examinations and 18,097 unique images. An average of 12.2 images were obtained per patient. Fourteen infants met TW-ROP criteria on telemedicine examination. After bedside evaluation, 13 infants required laser photocoagulation and one was followed until he spontaneously regressed. Infants with TW-ROP had a significantly lower gestational age (24.9 weeks), birth weight (658.7 grams), and were more likely to be male than the no TW-ROP cohort (all p values <0.00001). Telemedicine had a calculated sensitivity of 100%, specificity of 99.8%, positive predicative value of 92.9% and negative predictive value of 100% for the detection of TW-ROP. No patient progressed to retinal detachment or any adverse anatomical outcome. Conclusions: The SUNDROP initiative demonstrated a high degree of diagnostic reliability and was able to capture all infants with TW-ROP. Telemedicine offers a cost-effective, reliable and accurate screening methodology for identifying infants with TW-ROP without sacrificing quality of care.
Natalia Fijalkowski; Luo Luo Zheng; Michael T Henderson; Matthew B Wallenstein; Theodore Leng; Darius M Moshfeghi
Related Documents :
24646619 - The impact of routine predischarge pulse oximetry screening in a regional neonatal unit.
8330579 - Twenty-four-hour ambulatory eeg monitoring in infantile spasms.
23687569 - Predictors of staphylococcus aureus rectovaginal colonization in pregnant women and ris...
24668299 - Screening of neonatal uk dried blood spots using a duplex trec screening assay.
17641269 - Severe speech delay as the presenting symptom of guanidinoacetate methyltransferase def...
23595939 - Evaluating the diagnostic gap: statewide incidence of undiagnosed critical congenital h...
8695999 - Serum interleukin-1 beta in neonatal sepsis.
4028749 - Diagnosis and therapy of necrotizing tracheobronchitis in ventilated neonates.
24650219 - Preconception maternal nutrition: a multi-site randomized controlled trial.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-18
Journal Detail:
Title:  Current eye research     Volume:  -     ISSN:  1460-2202     ISO Abbreviation:  Curr. Eye Res.     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-21     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8104312     Medline TA:  Curr Eye Res     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Department of Ophthalmology, Byers Eye Institute, Horngren Family Vitreoretinal Center and.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Automated morphometric magnetic resonance imaging analysis for the detection of periventricular nodu...
Next Document:  Dermatomyositis is associated with an increased risk of cardiovascular and cerebrovascular events: a...