Staffieri tracheo-oesophageal prosthesis for voice rehabilitation after laryngectomy: an evaluation of characteristics.
MedLine Citation:
PMID:  10367468     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Experimental results on voice prostheses used for the rehabilitation of patients that have lost their vocal function after total laryngectomy are presented. The purpose is to evaluate the difference in aerodynamic behaviour between Staffieri voice prosthesis and other commercial valves (Groningen standard, Groningen low pressure, Panje, Provox). Two different equipments for flow-rate measurement were designed and built to compare the performance of the valves. The valves have been experimentally tested under different conditions of airflow through the valve and tracheal side pressure. The data allow calculation of the airflow resistance, the parameter usually used to compare the performance of valves. The valves have also been experimentally tested under different conditions of fluid flow through the valve and oesophageal side pressure (reverse flow). Comparing the airflow resistance of Staffieri valves of different length L and different angular extension of the razor-thin silt alpha, it has been observed that the parameter alpha has a significant influence on the characteristics, while the effect of the length L is negligible. The airflow resistance of the Provox, Groningen low pressure and Staffieri alpha = 270 degrees valves are comparable; the Panje and Staffieri alpha = 180 degrees have similar behaviour; while the Groningen Standard is comparable to the Staffieri alpha = 90 degrees. Regarding reverse flow, it is pointed out that for most of the valves (Staffieri and commercial valves), at different oesophageal pressures the fluid flow is smaller than the flow that can be tolerated by patients without giving problems.
Authors:
G Belforte; M Carello; C Miani; A Staffieri
Related Documents :
3774688 - Muscular (hypertrophic) subaortic stenosis (hypertrophic obstructive cardiomyopathy): t...
3566578 - Use of an ellipsoid artificial heart.
3560878 - Design of a new pulse duplicator system for prosthetic heart valves.
10530338 - Pressure oscillations in anesthetized dogs and its conversion into quasi-periodic orbits.
22675608 - Ambulatory arterial stiffness index is higher in hypertensive patients with chronic kid...
17824808 - Contribution of captopril thiol group to the prevention of spontaneous hypertension.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Medical & biological engineering & computing     Volume:  36     ISSN:  0140-0118     ISO Abbreviation:  Med Biol Eng Comput     Publication Date:  1998 Nov 
Date Detail:
Created Date:  1999-06-28     Completed Date:  1999-06-28     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  7704869     Medline TA:  Med Biol Eng Comput     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  754-60     Citation Subset:  IM    
Affiliation:
Department of Mechanics, Technical University of Torino, Italy.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Airway Resistance
Evaluation Studies as Topic
Humans
Laryngectomy*
Larynx, Artificial*
Prosthesis Design

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic m...
Next Document:  A wideband high common mode rejection ratio amplifier and phase-locked loop demodulator for multifre...