Slow pathway modification for atrioventricular node re-entrant tachycardia: fast junctional tachycardia predicts adverse prognosis.
MedLine Citation:
PMID:  11119460     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To examine the cycle length of the junctional tachycardia often seen during successful slow pathway ablation for atrioventricular (AV) node re-entrant tachycardia, to determine whether shorter cycle lengths predict imminent atrioventricular block. DESIGN: Retrospective analysis of consecutive patients undergoing slow pathway modification. Intracardiac recordings were analysed after digital storage to determine the development of junctional tachycardia, its duration and maximum, minimum, and mean cycle length, occurrence of heart block, persistent slow pathway conduction, or later confirmed recurrence of AV node re-entrant tachycardia. SETTING: Regional cardiac centre. PATIENTS: 136 consecutive patients undergoing electrophysiological study found to have typical "slow-fast" AV node re-entrant tachycardia and subject to 137 slow pathway modification procedures. RESULTS: During successful temperature feedback controlled radiofrequency energy application, junctional tachycardia developed in 133 of 137 procedures. During ablation, 10 patients had evidence of AV block (first degree in seven patients and third degree in three), and 17 others had retrograde junctional atrial (JA) block. In these 27 patients, the junctional tachycardia was rapid, with a minimum (SD) cycle length 291 (47) ms. Conduction recovered quickly in all but two patients, one of whom required permanent pacing. Junctional tachycardia with normal AV and JA conduction in the other 111 patients was of a significantly slower minimum cycle length (537 (123) ms; p < 0.0001). CONCLUSIONS: Fast junctional tachycardia with cycle lengths under 350 ms seen during slow pathway modification is a predictor of conduction block, suggesting proximity to the compact node. Radiofrequency energy application should be terminated immediately to prevent development of AV block. An "auto cut off" facility for cycle lengths shorter than 350 ms could be built into radiofrequency ablation systems to increase safety.
Authors:
K J Lipscomb; A M Zaidi; A P Fitzpatrick; D Lefroy
Publication Detail:
Type:  Evaluation Studies; Journal Article    
Journal Detail:
Title:  Heart (British Cardiac Society)     Volume:  85     ISSN:  1468-201X     ISO Abbreviation:  Heart     Publication Date:  2001 Jan 
Date Detail:
Created Date:  2000-12-26     Completed Date:  2001-03-15     Revised Date:  2009-11-18    
Medline Journal Info:
Nlm Unique ID:  9602087     Medline TA:  Heart     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  44-7     Citation Subset:  IM    
Affiliation:
Manchester Heart Centre, University Department of Cardiology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Catheter Ablation
Electrocardiography
Female
Heart Block / etiology,  prevention & control*
Humans
Male
Middle Aged
Prognosis
Retrospective Studies
Tachycardia, Atrioventricular Nodal Reentry / complications,  diagnosis*,  surgery*