Document Detail


Slice-thickness evaluation in CT and MRI: an alternative computerised procedure.
MedLine Citation:
PMID:  22228130     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE: The efficient use of computed tomography (CT) and magnetic resonance imaging (MRI) equipment necessitates establishing adequate quality-control (QC) procedures. In particular, the accuracy of slice thickness (ST) requires scan exploration of phantoms containing test objects (plane, cone or spiral). To simplify such procedures, a novel phantom and a computerised LabView-based procedure have been devised, enabling determination of full width at half maximum (FWHM) in real time. MATERIALS AND METHODS: The phantom consists of a polymethyl methacrylate (PMMA) box, diagonally crossed by a PMMA septum dividing the box into two sections. The phantom images were acquired and processed using the LabView-based procedure. RESULTS: The LabView (LV) results were compared with those obtained by processing the same phantom images with commercial software, and the Fisher exact test (F test) was conducted on the resulting data sets to validate the proposed methodology. CONCLUSIONS: In all cases, there was no statistically significant variation between the two different procedures and the LV procedure, which can therefore be proposed as a valuable alternative to other commonly used procedures and be reliably used on any CT and MRI scanner.
Authors:
G Acri; M G Tripepi; F Causa; B Testagrossa; R Novario; G Vermiglio
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-1-7
Journal Detail:
Title:  La Radiologia medica     Volume:  -     ISSN:  1826-6983     ISO Abbreviation:  -     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-1-9     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0177625     Medline TA:  Radiol Med     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Environmental, Health, Social and Industrial Department, University of Messina, Policlinico Universitario - Torre Biologica, Viale Gazzi, 98125, Messina, Italy, gacri@unime.it.
Vernacular Title:
Determinazione dello spessore dello strato in TC e RM: una procedura computerizzata alternativa.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Imaging in congenital deformities of the spinal cord.
Next Document:  Endovascular treatment of visceral artery aneurysms and pseudoaneurysms: our experience.