A preliminary study of the chromatographic performance and permeability of a continuous silica xerogel column under reversed-phase HPLC conditions was performed. A porous chromatographic support was synthesized inside a 0.32 mm i.d. × 13 cm fused silica tube from potassium silicate solution and derivatized with dimethyloctadecylchlorosilane. The plate height at 0.01 cm/s (0.5 μL/min), near the apparent optimum linear velocity, was about 65 μm. The column efficiencies in terms of numbers of plates per meter were 5000 and 13 000 for ethyl benzoate (k = 0.8) and naphthalene (k = 2.0), respectively, at 0.5 μL/min. The major parameter affecting column efficiency was the heterogeneous morphology of the xerogel, modifications to which are expected to improve chromatographic performance. The column provided efficiencies comparable to those reported for continuous polymeric columns but less than that previously reported for a continuous silica column. Gradient elution mode was demonstrated with a mixture of polycyclic aromatic hydrocarbons. The column was highly permeable, exhibiting a linear dependence of pressure to flow rate and a back pressure of only 632 psi at 10 μL/min when a 95% aqueous mobile phase was used.
Authors:
S M Fields
Related Documents :
1448847 - Determination of lorajmine and its metabolite ajmaline in plasma and urine by a new hig...
8454707 - Determination of leucovorin and 5-fluorouracil in plasma by high-performance liquid chr...
22738787 - Quantitative analysis of four major diterpenoids in andrographis paniculata by (1)h nmr...
8432017 - Selective removal of beta 2-microglobulin from plasma specimens of long-term hemodialys...
11220827 - Bulk analysis by ir laser ablation inductively coupled plasma atomic emission spectrome...
22614917 - Esi lc-ms and ms/ms characterization of antifungal cyclic lipopeptides produced by baci...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Analytical chemistry     Volume:  68     ISSN:  0003-2700     ISO Abbreviation:  Anal. Chem.     Publication Date:  1996 Aug 
Date Detail:
Created Date:  2011-05-30     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0370536     Medline TA:  Anal Chem     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2709-12     Citation Subset:  -    
Affiliation:
Hoechst Marion Roussel, Analytical and Structural Sciences, 2110 East Galbraith Road, Cincinnati, Ohio 45215.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Screen-printable sol-gel enzyme-containing carbon inks.
Next Document:  Solenoid pumps for flow injection analysis.