Document Detail


Signals from dual gated TCD systems: curious observations and possible explanations.
MedLine Citation:
PMID:  9080614     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Dual gated transcranial Doppler (TCD) systems have the potential to distinguish definitively embolic events in the cerebral circulation from artefact. While developing such a system, three curious observations were made and are the subject of this article. The first was that the velocity of propagation of an embolus in an artery as calculated from the ultrasonic Doppler shift was, in many cases, dramatically different from the velocity calculated using a time of flight method. The second observation was that the durations of embolic signals measured in two gates were often very different, despite the received gates being identical in length. The third observation was that some emboli detected in the deeper gate did not appear in the more superficial gate, and, more surprisingly (as has recently been reported by another group), some emboli that had not previously appeared in the deeper gate appeared in the more superficial gate. It is hypothesised that all of these effects can be explained in terms of the geometry of the middle cerebral artery in relation to the interrogating ultrasound beam. None of these effects should detract from the usefulness of TCD, but will need to be widely appreciated if dual gated measurements of cerebral emboli are to be interpreted correctly.
Authors:
J L Smith; D H Evans; A R Naylor
Related Documents :
6234754 - Balloon catheter technique for dilatation of constricted cerebral arteries after aneury...
1917674 - A comparative study of the circle of willis in fetal and adult life. the configuration ...
8553384 - Comparative study of power-based versus mean frequency-based transcranial color-coded d...
7236064 - Ischemic oculopathy. a manifestation of carotid artery disease.
3413734 - Studies on coagulation, fibrinolysis, kallikrein-kinin and complement activation in sys...
3913064 - The prevalence of carotid artery disease in patients presenting with amaurosis fugax.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Ultrasound in medicine & biology     Volume:  23     ISSN:  0301-5629     ISO Abbreviation:  Ultrasound Med Biol     Publication Date:  1997  
Date Detail:
Created Date:  1997-06-13     Completed Date:  1997-06-13     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0410553     Medline TA:  Ultrasound Med Biol     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  15-24     Citation Subset:  IM    
Affiliation:
Department of Surgery, Faculty of Medicine, University of Leicester, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Cerebrovascular Circulation
Humans
Intracranial Embolism and Thrombosis / ultrasonography*
Models, Theoretical
Ultrasonography, Doppler, Transcranial*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Sonographic determination of cutaneous and subcutaneous fibrosis after accidental exposure to ionisi...
Next Document:  Relation of the flow field distal to a moderate stenosis to the Doppler power.