Document Detail


Should stimulation therapy for congestive heart failure be combined with defibrillation backup?
MedLine Citation:
PMID:  11084118     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Biventricular pacing has been proposed to resynchronize ventricular contraction in patients with congestive heart failure (CHF) and interventricular conduction delay. However, the sudden death rate is still high despite the improvement in cardiac performance. Devices combining biventricular pacing with implantable cardioverter defibrillator (ICD) backup are now under clinical investigation to demonstrate whether they can decrease sudden death. From the first implant of an ICD with biventricular transvenous pacing on August 1998 to April 2000, 96 patients underwent such implants: 67 (70%) received pacemakers alone and 29 (30%), who had class I ICD indications, received combined pacemaker/ICD systems. During a mean follow-up of 283 +/- 170 days, 13 (14%) patients died: 5 of 29 (17%) in the ICD group and 8 of 67 (12%) in the pacemaker group. A total of 15 patients (52%) had ICD shocks and 6 patients (21%) had 113 episodes of ventricular tachyarrhythmias, of which 96 (85%) were converted to sinus rhythm with antitachypacing. The echocardiograms showed a narrowing of the delay between the onset of right and left ventricular outflow from 40 +/- 37 msec to 17 +/- 16 msec (p = 0.03) and a reduction of the mitral regurgitation area from 7 +/- 3.8 cm2 to 5 +/- 4 cm2 (p = 0.04) at 3 months. Functional class improved from 2.8 +/- 0.7 to 1.6 +/- 0.5 (p <0.001) 3 months after implant. Thus, ischemic patients with reduced left ventricular ejection fraction and ventricular tachyarrhythmias seem good candidates for biventricular pacing with ICD backup. The sudden death risk for those with idiopathic dilated cardiomyopathy, however, is difficult to stratify, and the choice of ICD backup has to be considered on the basis of patient safety, as well as of costs.
Authors:
F Gaita; M Bocchiardo; M C Porciani; L Vivalda; A Colella; P Di Donna; D Caponi; M Bruzzone; L Padeletti
Related Documents :
19602028 - Synchronous ventricular pacing without crossing the tricuspid valve or entering the cor...
3885708 - Improved myocardial contractility with glucose-insulin-potassium infusion during pacing...
8240228 - Myocardial carnitine metabolism in congestive heart failure induced by incessant tachyc...
2405038 - Current status of sensor-modulated rate-adaptive cardiac pacing.
9253388 - Cardiovascular morbidity and mortality among hypertensive patients in general practice:...
1449288 - Device-supported myocardial revascularization: safe help for sick hearts.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The American journal of cardiology     Volume:  86     ISSN:  0002-9149     ISO Abbreviation:  Am. J. Cardiol.     Publication Date:  2000 Nov 
Date Detail:
Created Date:  2005-11-04     Completed Date:  2005-12-20     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  0207277     Medline TA:  Am J Cardiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  165K-158K     Citation Subset:  AIM; IM    
Affiliation:
Division of Cardiology, Ospedale Civile of Asti, Asti, Italy.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Arrhythmias, Cardiac / etiology,  therapy*
Cardiac Pacing, Artificial / methods*
Defibrillators, Implantable
Electric Countershock / instrumentation*
Female
Heart Failure / complications*
Humans
Male
Pacemaker, Artificial

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Transvenous left ventricular lead implantation with the EASYTRAK lead system: the European experienc...
Next Document:  Lumpectomy with tamoxifen as primary treatment for elderly women with early-stage breast cancer.