Document Detail


Should recent defibrillator and lead advisories affect decisions to refer patients for implantable cardioverter-defibrillator therapy?
MedLine Citation:
PMID:  19907318     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE OF REVIEW: Implantable cardioverter-defibrillators (ICDs) have been shown to improve survival by terminating life-threatening ventricular arrhythmias. As ICDs have become more complex, there has been an increase in the incidence of device and lead malfunctions. Advisories and recalls are issued by device manufacturers to alert physicians to potential malfunction, but the management is typically left to the physician. We reviewed recent data on ICD and lead advisories, in addition to studies evaluating associated consequences, to determine whether advisories affect the benefit of device therapy and how best to manage device advisories. RECENT FINDINGS: Despite the increasing number of advisories and attention to device and lead failure, the overall reliability and efficacy of ICDs for appropriate patients remain high. Careful consideration must be employed when decisions are made to replace generators or extract leads, as these additional procedures can lead to more significant adverse complications compared with the advisory and potential for malfunction. SUMMARY: Patients continue to benefit from ICD implantation despite recent advisories for potential device and lead malfunction. The decision for ICD implantation should still be based on the patient's risk of experiencing a life-threatening arrhythmia. Patients should be counseled prior to implant of the potential for device and lead malfunction, and careful consideration must be employed in the setting of an advisory prior to replacing an affected device or lead.
Authors:
Mitesh S Amin; Kenneth A Ellenbogen
Related Documents :
19853688 - Rationale and design of the duke electrophysiology genetic and genomic studies (epgen) ...
22544088 - The use of acellular dermal matrix in immediate two-stage tissue expander breast recons...
21445598 - A case of subacute thrombosis associated with clopidogrel resistance after implantation...
22414518 - Evaluating edta as a substitute for phosphoric acid-etching of enamel and dentin.
17499478 - Effects of environmental tobacco smoke in vitro on rhesus monkey sperm function.
10520578 - In vitro sperm-binding assay to distinguish differences in populations of human sperm o...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't; Review    
Journal Detail:
Title:  Current opinion in cardiology     Volume:  25     ISSN:  1531-7080     ISO Abbreviation:  Curr. Opin. Cardiol.     Publication Date:  2010 Jan 
Date Detail:
Created Date:  2009-12-09     Completed Date:  2010-02-19     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8608087     Medline TA:  Curr Opin Cardiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  23-8     Citation Subset:  IM    
Affiliation:
Department of Internal Medicine, Division of Cardiology, Virginia Commonwealth University Medical Center, Richmond, Virginia 23298-0053, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Defibrillators, Implantable / adverse effects,  contraindications*,  psychology
Equipment Failure
Humans
Risk Assessment

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Electrical remodeling in the failing heart.
Next Document:  Somatostatin and the gastrointestinal tract.