Document Detail


Shifted helical computed tomography to optimize cardiac positron emission tomography-computed tomography coregistration: quantitative improvement and limitations.
MedLine Citation:
PMID:  20868626     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Positron emission tomography-computed tomography (PET-CT) uses CT attenuation correction but suffers from misregistration artifacts. However, the quantitative accuracy of helical versus cine CT in the same patient after optimized coregistration by shifting both CT data as needed for each patient is unknown. We studied 293 patients undergoing cardiac perfusion PET-CT using helical CT attenuation correction for comparison to cine CT. Objective, quantitative criteria identified perfusion abnormalities that were associated visually with PET-CT misregistration. Custom software shifted CT data to optimize coregistration with quantitative artifact improvement. The majority (58.1%) of cases with both helical and shifted helical CT data (n  = 93) had artifacts that improved or resolved by software shifting helical CT data. Translation of shifted helical CT was greatest in the x-direction (8.8 ± 3.3 mm) and less in the y- and z-directions (approximately 3.5 mm). The magnitude of differences in quantitative end points was greatest for helical (p  =  .0001, n  =  177 studies), less for shifted helical but significant (p  =  .0001, n  =  93 studies), and least for cine (not significant, n  =  161 studies) CT compared to optimal attenuation correction for each patient. Frequent artifacts owing to attenuation-emission misregistration are substantially corrected by software shifting helical CT scans to achieve proper coregistration that, however, remains on average significantly inferior to cine CT attenuation quantitatively.
Authors:
Nils P Johnson; Tinsu Pan; K Lance Gould
Related Documents :
22135746 - Imaging the visual pathway in neuromyelitis optica.
15128986 - Gunshot wounds of abdomen: evaluation of stable patients with triple-contrast helical ct.
17621616 - Ureteric colic: new trends in diagnosis and treatment.
7676016 - Helical (spiral) ct of the musculoskeletal system.
21249356 - Ménétrier's disease diagnosed by enteroclysis ct: a case report and review of the lit...
11972466 - Accuracy of ct in local staging of gallbladder carcinoma.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Molecular imaging     Volume:  9     ISSN:  1536-0121     ISO Abbreviation:  Mol Imaging     Publication Date:  2010 Oct 
Date Detail:
Created Date:  2010-09-27     Completed Date:  2011-01-12     Revised Date:  2011-04-07    
Medline Journal Info:
Nlm Unique ID:  101120118     Medline TA:  Mol Imaging     Country:  United States    
Other Details:
Languages:  eng     Pagination:  256-67     Citation Subset:  IM    
Affiliation:
Division of Cardiology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Humans
Positron-Emission Tomography / methods*
Software
Tomography, Spiral Computed / methods*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation.
Next Document:  Magnetic resonance imaging of monocytes labeled with ultrasmall superparamagnetic particles of iron ...