Document Detail


Setting positive end-expiratory pressure during jet ventilation to replicate the mean airway pressure of oscillatory ventilation.
MedLine Citation:
PMID:  17194318     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: High-frequency ventilation can be delivered with either oscillatory ventilation (HFOV) or jet ventilation (HFJV). Traditional clinician biases may limit the range of function of these important ventilation modes. We hypothesized that (1) the jet ventilator can be an accurate monitor of mean airway pressure (P (aw)) during HFOV, and (2) a mathematical relationship can be used to determine the positive end-expiratory pressure (PEEP) setting required for HFJV to reproduce the P (aw) of HFOV. METHODS: In phase 1 of our experiment, we used a differential pressure pneumotachometer and a jet adapter in-line between an oscillator circuit and a pediatric lung model to measure P (aw), PEEP, and peak inspiratory pressure (PIP). Thirty-six HFOV setting combinations were studied, in random order. We analyzed the correlation between the pneumotachometer and HFJV measurements. In phase 2 we used the jet as the monitoring device during each of the same 36 combinations of HFOV settings, and recorded P (aw), PIP, and DeltaP. Then, for each combination of settings, the jet ventilator was placed in-line with a conventional ventilator and was set at the same rate and PIP as was monitored during HFOV. To determine the appropriate PEEP setting, we calculated the P (aw) contributed by the PIP, respiratory rate, and inspiratory time set for HFJV, and subtracted this from the goal P (aw). This value was the PEEP predicted for HFJV to match the HFOV P (aw). RESULTS: The correlation coefficient between the pneumotachometer and HFJV measurements was r = 0.99 (mean difference 0.62 +/- 0.30 cm H(2)O, p < 0.001). The predicted and actual PEEP required were highly correlated (r = 0.99, p < 0.001). The mean difference in these values is not statistically significantly different from zero (mean difference 0.25 +/- 1.02 cm H(2)O, p > 0.15). CONCLUSIONS: HFJV is an accurate monitor during HFOV. These measurements can be used to calculate the predicted PEEP necessary to match P (aw) on the 2 ventilators. Replicating the P (aw) with adequate PEEP on HFJV may help simplify transitioning between ventilators when clinically indicated.
Authors:
Andora L Bass; Michael A Gentile; John P Heinz; Damian M Craig; Donna S Hamel; Ira M Cheifetz
Related Documents :
19021898 - End-expiratory lung volume during mechanical ventilation: a comparison with reference v...
20219698 - Partitioning of exhaled no in ventilated patients undergoing cardiac surgery.
14674978 - Effects of end-inspiratory and end-expiratory pressures on alveolar recruitment and der...
10712338 - Influence of body weight on the severity of dyspnea in chronic obstructive pulmonary di...
4055588 - Effects of upper or lower airway anesthesia on hypercapnic ventilation in humans.
10489108 - A novel promoter variant of the natriuretic peptide clearance receptor gene is associat...
Publication Detail:
Type:  In Vitro; Journal Article    
Journal Detail:
Title:  Respiratory care     Volume:  52     ISSN:  0020-1324     ISO Abbreviation:  Respir Care     Publication Date:  2007 Jan 
Date Detail:
Created Date:  2006-12-29     Completed Date:  2007-03-20     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7510357     Medline TA:  Respir Care     Country:  United States    
Other Details:
Languages:  eng     Pagination:  50-5     Citation Subset:  IM    
Affiliation:
Pediatric Critical Care, East Carolina University, Brody School of Medicine, 600 Moye Boulevard, Greenville NC 27834, USA. bassa@ecu.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Airway Resistance / physiology*
Equipment Design
High-Frequency Jet Ventilation / instrumentation*
Humans
Infant, Newborn
Models, Anatomic*
Models, Theoretical*
Positive-Pressure Respiration / methods*
Respiratory Distress Syndrome, Newborn / physiopathology,  therapy*
Treatment Outcome

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Measurement of pulsatile tidal volume, pressure amplitude, and gas flow during high-frequency percus...
Next Document:  Neonatal neoplasms: a single-centre experience