Document Detail


Sensitivity of fluorophore-quencher labeled microbubbles to externally applied static pressure.
MedLine Citation:
PMID:  19746779     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A fluorophore-quencher (F-Q) labeled microbubble system is proposed as a sensor for measuring externally applied static pressure distribution in a tumor. To quantify the sensitivity of such an F-Q bubble system to the externally applied pressure, a model describing bubble response to the static pressure was derived. Additionally, a model connecting the fluorescence lifetime and bubble radius was developed for the basic F-Q bubble system. The sensitivity is quantified based on these models given typical parameters. Results show that it is possible to resolve as low as 1 mm Hg pressure variation when both the F-Q bubble system and the measurement system are optimized. Strategies for optimizing an F-Q bubble system are discussed.
Authors:
Baohong Yuan
Related Documents :
10477809 - Effect of compression speeds on the compaction properties of a 1:1 paracetamol-microcry...
15726959 - Quantitative absorption spectroscopy of residual water vapor in high-purity gases: pres...
16708919 - Paranasal sinus ventilation by humming.
2858559 - The compaction properties of polyethylene glycols.
20469279 - Reduction of gas contamination in the operating room.
7498069 - An evaluation of the aquatic hazard of cumene (isopropyl benzene).
21125469 - Role of controlled lumbar csf drainage for icp control in aneurysmal sah.
10774619 - Synergistic septicemic action of the gram-positive bacterial cell wall components pepti...
21285669 - Potential benefits of aliskiren beyond blood pressure reduction.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Medical physics     Volume:  36     ISSN:  0094-2405     ISO Abbreviation:  -     Publication Date:  2009 Aug 
Date Detail:
Created Date:  2009-09-14     Completed Date:  2009-09-30     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0425746     Medline TA:  Med Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  3455-69     Citation Subset:  IM    
Affiliation:
Department of Biomedical Engineering, Catholic University of America, Washington, DC 20064, USA. yuan@cua.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Biomechanics
Feasibility Studies
Fluorescence
Fluorescent Dyes / metabolism*
Microbubbles*
Models, Biological
Neoplasms / metabolism,  physiopathology
Pressure*
Staining and Labeling
Surface Tension
Time Factors
Chemical
Reg. No./Substance:
0/Fluorescent Dyes