Document Detail


Screw loosening in the Dynesys stabilization system: radiographic evidence and effect on outcomes.
MedLine Citation:
PMID:  20568916     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
OBJECT: Dynamic stabilization systems are used to stabilize degenerative lumbar spondylosis. Loosening of the pedicle screws in such nonfusion implants is predictable. This retrospective study evaluated the incidence of screw loosening and its effect on clinical outcomes.
METHODS: Charts, radiographic films, and medical records of 71 consecutive patients who underwent decompression using Dynesys dynamic stabilization for 1- or 2-level lumbar spondylosis were reviewed. Radiographic films were evaluated and compared to detect screw loosening. A visual analog scale (VAS) for back pain and the Oswestry Disability Index (ODI) were used for measuring clinical outcome. Statistical analysis was conducted using the chi-square test and Student t-test.
RESULTS: The 71 patients in the study sample had a mean age of 59.2 +/- 11.65 years (range 23-80 years), with slight female predominance (39 women, 32 men). The mean follow-up duration was 16.6 months (range 8-29 months). There were loose screws in 14 of 71 patients (19.7%), for a rate of 4.6% per screw (17 of 368 screws). Most screw loosening occurred in patients >/= 55 years old (13 of 14 patients) although age and sex had no effect on screw loosening (p = 0.233 and 0.109, respectively). Both the loose screw and solid screw groups experienced significant improvement after the surgery in VAS and ODI scores. On the VAS, scores improved from 5.9 +/- 2.99 to 2.1 +/- 2.14 in the loose screw group (p = 0.003), and from 5.7 +/- 3.45 to 2.9 +/- 2.68 in the solid screw group (p < 0.001). For the ODI scale, scores improved from 43.5 +/- 16.78% to 28.0 +/- 18.18% (p = 0.006) in the loose screw group, and from 52.1 +/- 20.92% to 24.6 +/- 19.78% (p < 0.001) in the solid screw group. There were no significant differences between the 2 groups (p = 0.334 for VAS, p = 0.567 for ODI).
CONCLUSIONS: The preliminary study of this pedicle-based dynamic stabilization device for 1- and 2-level lumbar spondylosis shows radiographic evidence of screw loosening in 19.7% of patients and 4.6% of screws. Nonetheless, the loosening of screws has no adverse effect on clinical improvement.
Authors:
Chin-Chu Ko; Hsiao-Wen Tsai; Wen-Cheng Huang; Jau-Ching Wu; Yu-Chun Chen; Yang-Hsin Shih; Hung-Chieh Chen; Ching-Lan Wu; Henrich Cheng
Related Documents :
17607106 - Single balloon kyphoplasty using far-lateral extrapedicular approach: technical note an...
15371706 - Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal f...
11010056 - Spine fusion for discogenic low back pain: outcomes in patients treated with or without...
16479396 - Posterior atlantoaxial three-point fixation: comparison of intraoperative performance b...
7674156 - Endocapsular ring approach to the subluxed cataractous lens.
21969096 - Refractory hypotension in a patient with wernicke's encephalopathy.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Neurosurgical focus     Volume:  28     ISSN:  1092-0684     ISO Abbreviation:  Neurosurg Focus     Publication Date:  2010 Jun 
Date Detail:
Created Date:  2010-06-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100896471     Medline TA:  Neurosurg Focus     Country:  United States    
Other Details:
Languages:  eng     Pagination:  E10     Citation Subset:  IM    
Affiliation:
Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Dynamic stabilization.
Next Document:  Biomechanics of a posture-controlling cervical artificial disc: mechanical, in vitro, and finite-ele...