Abstract/OtherAbstract:
A two-frequency x-mode reflectometer operating from 100 to 146 GHz is deployed on Alcator C-Mod to measure the density profile and fluctuations in the scrape-off layer (SOL) immediately in front of the new J-port ICRF antenna and the new C-port lower hybrid launcher. The reflectometer covers densities from 10(16) to 10(20) m(-3) at 5-5.4 T. To provide the greatest flexibility and capability to deal with density fluctuations approaching 100% peak-to-peak in the SOL, both full-phase and differential-phase measurement capabilities with sweep speeds of approximately 10 micros to >1 ms are implemented. The differential-phase measurement uses a difference frequency of 500 MHz, corresponding to cutoff layer separations ranging from about 0.1 to 1 mm. The reflectometer has six sets of launchers: three on the ICRF antenna and three on the lower hybrid launcher. Both the ICRF antenna and the lower hybrid launcher incorporate reflectometer antennas at their top, bottom, and midplane locations.
Authors:
G R Hanson; J B Wilgen; C Lau; Y Lin; G M Wallace; S J Wukitch
Related Documents :
8547048 - Early events in the invasion of the human nail plate by trichophyton mentagrophytes.
17189768 - Effect of temperature on the spoilage rate of whole, unprocessed crabs: carcinus maenas...
10909448 - Diagnosis and management of abnormal embryonic development characterized by formation o...
2760568 - External quality assessment of absorbance measurements on spectral and spectral-line ph...
20450828 - Incidence, causes and consequences of pregnancy failure in viviparous lizards: implicat...
16466428 - Maternal caffeine consumption and fetal death: a case-control study in uruguay.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Review of scientific instruments     Volume:  79     ISSN:  1089-7623     ISO Abbreviation:  Rev Sci Instrum     Publication Date:  2008 Oct 
Date Detail:
Created Date:  2008-12-02     Completed Date:  2009-02-17     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0405571     Medline TA:  Rev Sci Instrum     Country:  United States    
Other Details:
Languages:  eng     Pagination:  10F114     Citation Subset:  -    
Affiliation:
Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Detection of zonal flow spectra in DIII-D by a dual-channel Doppler backscattering system.
Next Document:  Development of multichannel intermediate frequency system for electron cyclotron emission radiometer...