Sampling rate effects on surface EMG timing and amplitude measures.
MedLine Citation:
PMID:  12828904     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To determine if oversampling the surface electromyographic signal provides any benefit in analyzing common electromyographic timing and amplitude measures used in kinesiological studies. DESIGN: A within subjects (n=8) repeated measures design was used to examine surface electromyographic signals captured under four contraction modes and acquired with five different analog-to-digital sampling rates. BACKGROUND: There is a growing trend to sample surface electromyography at rates higher than the Nyquist rate. Though there is limited evidence to support oversampling, the necessity or benefit of doing so remains unclear. METHODS: Surface electromyography was recorded from the triceps brachii during maximal, submaximal, and fatiguing isometric contractions, as well as dynamic contractions. The analog signals were bandpassed between 20 Hz and 2 kHz, and oversampled at 6 kHz. The signals were then digitally resampled at 3 kHz, 1 kHz, 500 Hz, and 250 Hz without benefit of an anti-aliasing filter. Amplitude and timing variables measured from both the rectified and smoothed signal were compared across sampling rates. RESULTS: Oversampling produced no significant changes in timing and amplitude measures of the rectified or smoothed electromyographic signal. For the smoothed signal, minor undersampling at half the Nyquist rate was sufficient to accurately capture most timing and signal strength measures. CONCLUSIONS: Oversampling is unnecessary to gather typical amplitude and timing measures from the surface electromyographic signal. Electromyography sampled below half the Nyquist rate is likely to result in a poor temporal and amplitude representation of the signal. RELEVANCE: Computer memory and processing resources for analyzing amplitude and timing information need not be expended in oversampling surface electromyography, and results of previous studies need not be outright dismissed because of minor undersampling violations or the lack of an anti-aliasing filter.
Authors:
Jeffrey C Ives; Janet K Wigglesworth
Related Documents :
16054394 - Influences of experimental factors on spinal stretch reflex latency and amplitude in th...
8035234 - Muscle activation patterns for reaching: the representation of distance and time.
8922994 - Azimuthal sensitivity of rat pinna reflex: emg recordings from cervicoauricular muscles.
18829854 - Identification of the plant for upright stance in humans: multiple movement patterns fr...
25389374 - The sun compass revisited.
21871794 - Influences of light and oxygen conditions on photosynthetic bacteria macromolecule degr...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  18     ISSN:  0268-0033     ISO Abbreviation:  Clin Biomech (Bristol, Avon)     Publication Date:  2003 Jul 
Date Detail:
Created Date:  2003-06-27     Completed Date:  2003-08-26     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  England    
Other Details:
Languages:  eng     Pagination:  543-52     Citation Subset:  IM    
Affiliation:
Department of Exercise and Sport Sciences, Center for Health Sciences, Ithaca College, Ithaca, NY 14850, USA. jives@ithaca.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Analog-Digital Conversion*
Electromyography / methods*
Female
Humans
Male
Signal Processing, Computer-Assisted

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Measurement of muscle activity with magnetic resonance elastography.
Next Document:  Measurement of the mechanical condition of articular cartilage with an ultrasonic probe: quantitativ...