Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment.
MedLine Citation:
PMID:  17034016     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps were more than a factor 2 lower as the gravitational force on the device whereas, magnetic forces on the older devices showed over 10 times the force induced by earth acceleration of gravity. No torque effects could be found for the newly designed clamps. Temperature measurements at the tips of Schanz screws in the 1.5 T MR scanner showed a rise of 0.7 degrees C for a pelvic frame and of 2.1 degrees C for a diamond knee bridge frame when normalized to a specific absorption rate (SAR) of 2 W/kg. The normalized temperature increases in the 3 T MR scanner were 0.9 degrees C for the pelvic frame and 1.1 degrees C for the knee bridge frame. Large external fixation frames assembled with the newly designed clamps (390 Series Clamps), carbon fiber reinforced rods, and implant quality 316L stainless steel Schanz screws met prevailing force and torque limits when tested in a 3-T field, and demonstrated temperature increase that met IEC-60601 guidelines for extremities. The influence of frame-induced eddy currents on the risk of peripheral nerve stimulation was not investigated.
Authors:
Roger Luechinger; Peter Boesiger; John A Disegi
Related Documents :
14680906 - 3.0 t magnetic resonance in neuroradiology.
21343486 - Role of mri in intracavitary brachytherapy for cervical cancer: what the radiologist ne...
12148746 - X-ray micro-ct with a displaced detector array.
15565156 - Magnetoreception and its trigeminal mediation in the homing pigeon.
2653326 - An ultrasonographic method for detection of achilles tendon xanthomas in familial hyper...
7384486 - Evaluation of dissections and aneurysms of the thoracic aorta by conventional and dynam...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of biomedical materials research. Part B, Applied biomaterials     Volume:  82     ISSN:  1552-4973     ISO Abbreviation:  J. Biomed. Mater. Res. Part B Appl. Biomater.     Publication Date:  2007 Jul 
Date Detail:
Created Date:  2007-06-12     Completed Date:  2007-10-09     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  101234238     Medline TA:  J Biomed Mater Res B Appl Biomater     Country:  United States    
Other Details:
Languages:  eng     Pagination:  17-22     Citation Subset:  IM    
Copyright Information:
Copyright 2006 Wiley Periodicals, Inc.
Affiliation:
Institute for Biomedical Engineering, University and ETH Zurich, Switzerland. luechinger@biomed.ee.ethz.ch
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
External Fixators*
Hot Temperature*
Magnetic Resonance Imaging*
Magnetics*
Materials Testing*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Growing tissue-like constructs with Hep3B/HepG2 liver cells on PHBV microspheres of different sizes.
Next Document:  Adolescent girls and criminal activity: role of MAOA-LPR genotype and psychosocial factors.