Document Detail


Safety and efficacy of a novel intravascular cooling device to control body temperature in neurologic intensive care patients: a prospective pilot study.
MedLine Citation:
PMID:  12441758     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To determine the safety and efficacy of a novel intravascular cooling device (Cool Line catheter with Cool Gard system) to control body temperature (temperature goal <37 degrees C) in neurologic intensive care patients. DESIGN: A prospective, uncontrolled pilot study in 51 consecutive neurologic intensive care patients. SETTING: A neurologic intensive care unit at a tertiary care university hospital. PARTICIPANTS: Patients were 51 neurologic intensive care patients with an intracranial disease requiring a central venous catheter due to the primary (intracranial) disease. We excluded patients under the age of 19 yrs and those with active cardiac arrhythmia, full sepsis syndrome, bleeding diathesis and infection, or bleeding at the site of the intended catheter insertion. Male to female ratio was 31:20, and the median age was 55 yrs (range, 24-85 yrs). Forty-four of 51 patients (86.3%) had an initial Glasgow Coma Scale score of 3, three patients had a Glasgow Coma Scale score of 9, one patient presented with an initial Glasgow Coma Scale score of 11, two patients had an initial Glasgow Coma Scale score of 13, and one patient had an initial Glasgow Coma Scale score of 15. The mean initial tissue injury severity score was 45.1 and the median initial tissue injury severity score 45.0 (range, 19-70). INTERVENTIONS: Patients were enrolled prospectively in a consecutive way. Within 12 hrs after admission, the intravascular cooling device (Cool Line catheter) was placed, the temperature probe was located within the bladder (by Foley catheter), and the Cool Gard cooling device was initiated. This Cool Gard system circulates temperature-controlled sterile saline through two small balloons mounted on the distal end of the Cool Line catheter. The patient's blood is gently cooled as it is passed over the balloons. The Cool Gard system has been set with a target temperature of 36.5 degrees C. The primary purpose and end point of this study was to evaluate the cooling capacity of this intravascular cooling device. Efficacy is expressed by the calculation formula of fever burden, which is defined as the fever time product ( degrees C hours) under the fever curve. MEASUREMENTS AND MAIN RESULTS: The cooling device was in operation for a mean of 152.4 hrs. The ease of insertion was judged as easy in 42 of 51 patients; in a single patient, the catheter was malpositioned within the jugular vein, requiring early removal. The rate of infectious and noninfectious complications (nosocomial pneumonia, bacteremia, catheter-related ventriculitis, pulmonary embolism, etc.) was comparable to the rate usually observed in our neurologic intensive care patients with such severe intracranial diseases. The total fever burden within the entire study period of (on average) 152.4 hrs was 4.0 degrees C hrs/patient, being equivalent to 0.6 degrees C hrs/patient and day. Thirty of 51 patients showed an elevation of the body temperature (>37.9 degrees C) within 24 hrs after termination of the cooling study. One awake patient (subarachnoid hemorrhage, Glasgow Coma Scale score 15) experienced mild to moderate shivering throughout the entire period of 7 days. The mortality rate was 23.5%. CONCLUSION: This novel intravascular cooling device (Cool Line catheter and Cool Gard cooling device) was highly efficacious in prophylactically controlling the body temperature of neurologic intensive care patients with very severe intracranial disease (median Glasgow Coma Scale score, 3-15). Morbidity and mortality rates were consistent with the ranges reported in the literature for such neurologic intensive patients.
Authors:
Erich Schmutzhard; Klaus Engelhardt; Ronny Beer; Gregor Brössner; Bettina Pfausler; Heinz Spiss; Iris Unterberger; Andreas Kampfl
Related Documents :
25251168 - Prognostic significance of 25-hydroxivitamin d entirely explained by a higher comorbidi...
17229258 - Yam bean seed poisoning mimicking cyanide intoxication.
7734058 - Minamata disease: methylmercury poisoning in japan caused by environmental pollution.
7964918 - Inter-observer variation in the evaluation of neurological signs: patient-related factors.
8957388 - Left atrial spontaneous echo contrast in asymptomatic patients with a mechanical valve ...
20179008 - Acute kidney injury in sickle patients with painful crisis or acute chest syndrome and ...
Publication Detail:
Type:  Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Critical care medicine     Volume:  30     ISSN:  0090-3493     ISO Abbreviation:  Crit. Care Med.     Publication Date:  2002 Nov 
Date Detail:
Created Date:  2002-11-20     Completed Date:  2002-12-11     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0355501     Medline TA:  Crit Care Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2481-8     Citation Subset:  AIM; IM    
Affiliation:
Department of Neurology, University Hospital Innsbruck, Austria.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Aged, 80 and over
Brain Diseases / therapy*
Catheterization, Central Venous / methods*
Catheters, Indwelling
Cryotherapy / instrumentation*,  methods
Equipment Safety
Female
Fever / prevention & control*
Humans
Male
Middle Aged
Pilot Projects
Prospective Studies
Comments/Corrections
Comment In:
Crit Care Med. 2002 Nov;30(11):2598-600   [PMID:  12441780 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Marked activation of complement and leukocytes and an increase in the concentrations of soluble endo...
Next Document:  Amplification of the pulmonary vasodilatory response to inhaled iloprost by subthreshold phosphodies...