Document Detail


A SEM evaluation of debris removal from endodontic files after cleaning and steam sterilization procedures.
MedLine Citation:
PMID:  15497356     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: In recent times, it has been proposed to classify endodontic files as single-use items due to a perceived inability to adequately clean the instruments. The purpose of the present study was to quantify the surface debris on files removed from the manufacturer's packaging, and after cleaning using an ultrasonic bath or a thermal disinfector. METHODS: Stainless steel and rotary nickel-titanium files were examined after removal from the manufacturer's packaging, after instrumentation in broth-contaminated human teeth, and after various cleaning procedures. The cleaning procedures consisted of either a thermal disinfector cycle, ultrasonication with the files placed in a perforated container or ultrasonication with the files loosely placed in a beaker. The presence of manufacturing debris and biological debris was evaluated using scanning electron microscopy and quantified using image analysis software. RESULTS: The effectiveness of cleaning was not affected by variation in the size or taper of the files when an effective cleaning procedure was used. Cleaning the files in a thermal disinfector or by ultrasonication within a container did not consistently achieve complete removal of biological debris. Placing the files loosely in the ultrasonic bath achieved the most effective cleaning, an average of 98.33 per cent of the file surface area was freed of any biological debris. CONCLUSIONS: A conventional cleaning method is capable of effectively removing biological debris from endodontic files. The efficacy of ultrasonic cleaning was impaired when the files were placed within a perforated container.
Authors:
D A Van Eldik; P S Zilm; A H Rogers; P D Marin
Related Documents :
12227676 - Lipid profile of firefighters over time: opportunities for prevention.
960356 - Recertification of professional competence. american board of ophthalmology.
16128356 - Research diagnostic criteria for temporomandibular disorders: a calibration and reliabi...
11771066 - Recognizing and dealing with impaired clinicians: part ii--treatment options.
19698906 - Results of a thematic analysis to explore the experiences of patients with schizophreni...
15171066 - Reducing medication errors through naming, labeling, and packaging.
Publication Detail:
Type:  Evaluation Studies; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Australian dental journal     Volume:  49     ISSN:  0045-0421     ISO Abbreviation:  Aust Dent J     Publication Date:  2004 Sep 
Date Detail:
Created Date:  2004-10-22     Completed Date:  2004-11-16     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  0370612     Medline TA:  Aust Dent J     Country:  Australia    
Other Details:
Languages:  eng     Pagination:  128-35     Citation Subset:  D; IM    
Affiliation:
Dental School, The University of Adelaide.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Dental Alloys
Dental Pulp Cavity / pathology
Disinfection / instrumentation,  methods
Equipment Contamination / prevention & control*
Equipment Design
Hot Temperature
Humans
Image Processing, Computer-Assisted
Infection Control, Dental
Microscopy, Electron, Scanning
Nickel
Root Canal Preparation / instrumentation*
Stainless Steel
Steam*
Sterilization / methods*
Surface Properties
Titanium
Ultrasonics
Chemical
Reg. No./Substance:
0/Dental Alloys; 0/Steam; 12035-60-8/titanium nickelide; 12597-68-1/Stainless Steel; 7440-02-0/Nickel; 7440-32-6/Titanium

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Microbiological evaluation of endodontic files after cleaning and steam sterilization procedures.
Next Document:  A baseline study of the demographics of the oral health workforce in rural and remote Western Austra...