Document Detail


Ruptured aneurysm of the sinus of Valsalva. Clinical review, treatment results.
MedLine Citation:
PMID:  7775545     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Five patients were operated on because of ruptured aneurysm of the sinus of Valsalva. In the cases with no concomitant VSD the surgical access from the aorta was used. The aorta was opened and the Fogarty catheter was introduced to the fistula. The "wind sock" of the aneurysm was pulled back to the aorta and excised. The opening was closed with double-line pledgetted polypropylene sutures. In severe aortic incompetence mechanical prostheses were implanted. One patient had bacterial endocarditis with reopening of the fistula and aortic valve incompetence that required reoperation. All patients are in a good clinical state. We recommend the use of Dacron patches even in small aneurysms to avoid re-opening of the fistula.
Authors:
S Woś; M Matuszewski; R Bachowski; W Ceglarek; M Jasiński; W Domaradzki; K Toczek; B Korzeniowska; J Iwiński
Related Documents :
8741245 - Trans-systolic murmur during the valsalva maneuver in a patient with apical aneurysm--a...
3189145 - Doppler and two-dimensional echocardiographic features of sinus of valsalva aneurysm.
8070825 - Surgical correction of aneurysms of sinus of valsalva--a report of 22 cases.
15466805 - Extracorporeal expulsion of a vascular endograft used to treat a mycotic aneurysm.
24094805 - An unusual cause of congestive heart failure in a young woman.
686255 - Management of ruptured thoracic aortic aneurysms.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  The Journal of cardiovascular surgery     Volume:  35     ISSN:  0021-9509     ISO Abbreviation:  J Cardiovasc Surg (Torino)     Publication Date:  1994 Dec 
Date Detail:
Created Date:  1995-07-10     Completed Date:  1995-07-10     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0066127     Medline TA:  J Cardiovasc Surg (Torino)     Country:  ITALY    
Other Details:
Languages:  eng     Pagination:  219-22     Citation Subset:  IM    
Affiliation:
II Department of Cardiac Surgery, Silesian Medical Academy, Katowice, Poland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aortic Rupture / diagnosis,  etiology,  surgery*
Aortic Valve Insufficiency / etiology,  surgery
Echocardiography, Transesophageal
Female
Heart Catheterization
Heart Valve Prosthesis
Humans
Male
Polyethylene Terephthalates
Polypropylenes
Prostheses and Implants
Reoperation
Sinus of Valsalva*
Sutures
Chemical
Reg. No./Substance:
0/Polyethylene Terephthalates; 0/Polypropylenes

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The management of soft tissue complications related to pacemaker implantations.
Next Document:  Cryopreservation of veins as an alternative to autografts in coronary by-pass grafting.