The Multicenter Automatic Defibrillator Implantation Trial (MADIT II) investigators assert that their results justify the placement of artificial implantable defibrillator cardioverter devices in patients aged 75 years and older with prior myocardial infarction and left ventricular dysfunction (ejection fraction of 30 or less). The authors claim that the results of the trial do not justify this conclusion. The majority of patients were male (84%) and aged 64+/-10 years. Also, 2.8% of patients assigned to the defibrillator group and 1.5% had their device removed. Of the latter subgroup, nine patients (1.3%) received a heart transplant. Twelve had their artificial implantable defibrillator cardioverter device deactivated mostly because of terminal illness. Although the study results show a significant reduction in mortality over the control group (absolute reduction=5.6%), almost the same percentage required hospitalization because of manifestation of congestive heart failure (absolute value 5%; p=0.09). Also, 1.8% had lead problems, 0.7% had infections, and the benefits were only seen after the first year. Caution is needed before the results of this study are applied to a much older cohort comprised mainly of women in whom heart transplant is contraindicated and who have multiple health problems, including cognitive impairment. Artificial implantable cardioverter/defibrillator devices are expensive and this study's results need to be duplicated in other comparable cohorts.
Authors:
Lofty L Basta
Related Documents :
14520316 - Automated external defibrillation versus manual defibrillation for prolonged ventricula...
3706106 - Defibrillation with the sequential pulse technique: reproducibility with repeated shocks.
2457886 - Evaluation of global and regional left ventricular function using two-dimensional and m...
6209686 - Electronic control of ventricular tachyarrhythmias: overview and future directions.
19371826 - Tight glycemic control reduces heart inflammation and remodeling during acute myocardia...
11292936 - Left ventricular thrombosis after blunt chest trauma.
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  The American journal of geriatric cardiology     Volume:  12     ISSN:  1076-7460     ISO Abbreviation:  Am J Geriatr Cardiol     Publication Date:    2003 Nov-Dec
Date Detail:
Created Date:  2003-11-11     Completed Date:  2004-04-29     Revised Date:  2005-11-16    
Medline Journal Info:
Nlm Unique ID:  9215283     Medline TA:  Am J Geriatr Cardiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  363-5     Citation Subset:  IM    
Affiliation:
Project GRACE, Clearwater, FL and the University of Florida, Tampa, FL, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Defibrillators, Implantable*
Humans
Myocardial Infarction / prevention & control*,  therapy*
Stroke Volume*
Ventricular Dysfunction, Left / prevention & control*,  therapy*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Treating hypertension in the elderly: protagonist viewpoint.
Next Document:  Percutaneous coronary intervention in the elderly: procedural success and 1-year outcomes.