Document Detail


Role of apparent diffusion coefficient values and diffusion-weighted magnetic resonance imaging in differentiation between benign and malignant thyroid nodules.
MedLine Citation:
PMID:  22226435     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
OBJECTIVE: The purpose of the study was to differentiate between benign and malignant thyroid nodules using nodule-spinal cord signal intensity and nodule apparent diffusion coefficient (ADC) ratios on diffusion-weighted magnetic resonance imaging (DW-MRI).
MATERIALS AND METHODS: Forty-four patients (27 females, 17 males; mean age, 49 years) with nodules who underwent DW-MRI were included in this study. The images were acquired with 0, 50, 400 and 1000 s/mm(2)b values. ADC maps were calculated afterwards. Fine needle aspiration biopsies (FNAB) were performed at the same day with DW-MRI acquisition. The diagnosis in patients where malignity was detected after FNAB was confirmed by histopathologic analysis of the operation material. The signal intensities of the spinal cord and the nodule were measured additionally, over b-1000 diffusion-weighted images. Nodule/cord signal intensity (SI) ratios were obtained and the digital values were calculated by dividing to ADC values estimated for each nodule. Statistical analysis was performed.
RESULTS: The (nodule SI-cord SI)/nodule ADC ratio is calculated in the DW images, and a statistically significant relationship was found between this ratio and the histopathology of the nodules (P<.001). The ratio was determined as 0.27 in benign and 0.86 in malignant lesions. The result of receiver operating characteristic (ROC) analysis was statistically significant, and the area under curve (100%) was considerably high. The threshold value was calculated as 0.56 according to the ROC analysis. According to this threshold value, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy rates for (nodule SI/cord SI)/ADC ratios in differentiating benign from malignant thyroid nodules are calculated as 100%, 97%, 83%, 100%, and 98%, respectively.
CONCLUSION: We have found that (nodule/cord SI)/nodule ADC ratio has the highest values for sensitivity and specificity among the tests defined for characterization of nodules.
Authors:
Hakan Mutlu; Ali Kemal Sivrioglu; Guner Sonmez; Murat Velioglu; Huseyin Onur Sildiroglu; Cihat Cinar Basekim; Esref Kizilkaya
Related Documents :
12956265 - A hybrid breast biopsy system combining ultrasound and mri.
15590805 - Evaluation of magnetic navigation in an in vitro model of uterine artery embolization.
11317745 - Ghost imaging in mri.
21970745 - Manifestation of a sellar hemangioblastoma due to pituitary apoplexy: a case report.
9332255 - Optimising imaging parameters in experimental spiral ct.
11837585 - Evaluation of compressed lung ct image quality using quantitative analysis.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Clinical imaging     Volume:  36     ISSN:  1873-4499     ISO Abbreviation:  Clin Imaging     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-01-09     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8911831     Medline TA:  Clin Imaging     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1-7     Citation Subset:  IM    
Copyright Information:
Copyright © 2012. Published by Elsevier Inc.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Blood platelet production and morphology.
Next Document:  Mucoepidermoid carcinoma of the lung: common findings and unusual appearances on CT.