Abstract/OtherAbstract:
To develop an optimization algorithm for volumetric modulated arc therapy which incorporates an electromagnetic tracking (EMT) guided gating strategy and is robust to residual intra-fractional motion uncertainties. In a computer simulation, intra-fractional motion traces from prior treatments with EMT were converted to a probability distribution function (PDF), truncated using a patient specific action volume that encloses allowed deviations from the planned position, and renormalized to yield a new PDF with EMT-gated interventions. In lieu of a conventional planning target volume (PTV), multiple instances of clinical target volume (CTV) and organs at risk (OARs) were replicated and displaced to extreme positions inside the action volume representing possible delivery scenarios. When optimizing the volumetric modulated arc therapy plan, doses to the CTV and OARs were calculated as a sum of doses to the replicas weighted by the PDF to account for motion. A treatment plan meeting the clinical constraints was produced and compared to the counterpart conventional margin (PTV) plan. EMT traces from a separate testing database served to simulate motion during gated delivery. Dosimetric end points extracted from dose accumulations for each motion trace were utilized to evaluate potential clinical benefit. Five prostate cases from a hypofractionated protocol (42.5 Gy in 5 fractions) were retrospectively investigated. The patient specific gating window resulted in tight anterior and inferior action levels (∼1 mm) to protect rectal wall and bladder wall, and resulted in an average of four beam interruptions per fraction in the simulation. The robust-optimized plans achieved the same average CTV D95 coverage of 40.5 Gy as the PTV-optimized plans, but with reduced patient-averaged rectum wall D1cc by 2.2 Gy (range 0.7 to 4.7 Gy) and bladder wall mean dose by 2.9 Gy (range 2.0 to 3.4 Gy). Integration of an intra-fractional motion management strategy into the robust optimization process is feasible and may yield improved OAR sparing compared to the standard margin approach.
Authors:
Pengpeng Zhang; Margie Hunt; Laura Happersett; Jie Yang; Michael Zelefsky; Gig Mageras
Related Documents :
20379684 - Effect of light-curing units in shear bond strength of metallic brackets: an in vitro s...
1224134 - The mucociliary activity of the upper respiratory tract.
17546194 - Nanometer-thick au-films as antireflection coating for infrared light.
7492934 - High-pass resolution perimetry and light-sense perimetry in open-angle glaucoma.
15638624 - How effective for fold recognition is a potential of mean force that includes relative ...
24372324 - Photobiological interactions of blue light and photosynthetic photon flux: effects of m...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-10-21
Journal Detail:
Title:  Physics in medicine and biology     Volume:  58     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2013 Oct 
Date Detail:
Created Date:  2013-10-22     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  7803-7813     Citation Subset:  -    
Affiliation:
Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10021, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Hand infections.
Next Document:  Granulocyte Macrophage Colony-Stimulating Factor Auto-Antibodies and Disease Relapse in Inflammatory...