Robotic calibration of the motional Stark effect diagnostic on Alcator C-Mod.
MedLine Citation:
PMID:  24880367     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
The capability to calibrate diagnostics, such as the Motional Stark Effect (MSE) diagnostic, without using plasma or beam-into-gas discharges will become increasingly important on next step fusion facilities due to machine availability and operational constraints. A robotic calibration system consisting of a motorized three-axis positioning system and a polarization light source capable of generating arbitrary polarization states with a linear polarization angle accuracy of <0.05° has been constructed and has been used to calibrate the MSE diagnostic deployed on Alcator C-Mod. The polarization response of the complex diagnostic is shown to be fully captured using a Fourier expansion of the detector signals in terms of even harmonics of the input polarization angle. The system's high precision robotic control of position and orientation allow it to be used also to calibrate the geometry of the instrument's view. Combined with careful measurements of the narrow bandpass spectral filters, this system fully calibrates the diagnostic without any plasma discharges. The system's high repeatability, flexibility, and speed has been exploited to quantify several systematics in the MSE diagnostic response, providing a more complete understanding of the diagnostic performance.
Authors:
Robert T Mumgaard; Steven D Scott; Jinseok Ko
Related Documents :
16386827 - Bracket bond strength dependence on light power density.
18356997 - Wigner formulation of optical processing with light of arbitrary coherence.
15565147 - The building blocks of planets within the 'terrestrial' region of protoplanetary disks.
18264527 - Comparison of the heat generation of light curing units.
23576967 - Detection of spatial frequency in brain-damaged patients: influence of hemispheric asym...
10361657 - Clinical validity and stability of active and passive cervical range of motion with reg...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Review of scientific instruments     Volume:  85     ISSN:  1089-7623     ISO Abbreviation:  Rev Sci Instrum     Publication Date:  2014 May 
Date Detail:
Created Date:  2014-06-02     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0405571     Medline TA:  Rev Sci Instrum     Country:  United States    
Other Details:
Languages:  eng     Pagination:  053505     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The construction of an electrode biasing system for driving plasma rotation in J-TEXT tokamak.
Next Document:  A novel electron density reconstruction method for asymmetrical toroidal plasmas.