Document Detail


Revision total hip arthroplasty. Long-term results without cement.
MedLine Citation:
PMID:  8414429     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The authors present their results for cementless femoral revision arthroplasty using extensively porous coated implants. Patients have been prospectively followed for 5 to 11 years (mean 7.4 years). The revision rate was 5.7%, and the radiographic loosening rate was 1.1%, to give a mechanical failure rate of only 6.9%. As a result of the revision procedure, the pain level was improved for 89.1% of the patients, walking status was improved for 82.8% of the patients, and functional level was improved for 88.5% of the patients. These results compare very favorably with any reports on revision arthroplasty using cement with a similar length follow-up.
Authors:
J M Lawrence; C A Engh; G E Macalino
Related Documents :
22641239 - Responder analysis of the effects of denosumab on bone mineral density in men receiving...
11764339 - Tapered titanium cementless total hip replacements: a 10- to 13-year followup study.
1499199 - The clayton total hip arthroplasty. a ten-year follow-up study.
20720139 - Influence of obesity on femoral osteolysis five and ten years following total hip arthr...
9195259 - Aseptic loosening of bonelocr cemented hip prostheses.
18196429 - 5- to 9-year survivorship of single-radius, posterior-stabilized tka.
24684759 - Drug-eluting stents in patients on chronic hemodialysis: paclitaxel-eluting stents vs. ...
20036199 - Circumferential pulmonary vein isolation and linear left atrial ablation as a single-ca...
21377699 - Sternal dehiscence in patients with moderate and severe chronic obstructive pulmonary d...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Orthopedic clinics of North America     Volume:  24     ISSN:  0030-5898     ISO Abbreviation:  Orthop. Clin. North Am.     Publication Date:  1993 Oct 
Date Detail:
Created Date:  1993-11-22     Completed Date:  1993-11-22     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0254463     Medline TA:  Orthop Clin North Am     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  635-44     Citation Subset:  AIM; IM    
Affiliation:
Anderson Orthopaedic Clinic and Research Institute, Arlington, Virginia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Femur / physiopathology,  radiography,  surgery*
Follow-Up Studies
Hip Prosthesis*
Humans
Middle Aged
Pain, Postoperative / physiopathology,  surgery
Postoperative Complications
Prospective Studies
Prosthesis Failure
Reoperation
Time Factors
Walking

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The rationale for cementless revision total hip replacement with contemporary technology.
Next Document:  Thigh pain in cementless total hip arthroplasty. A comparison of two systems at 2 years' follow-up.