Document Detail


Review of thresholds and recommendations for revised exposure limits for laser and optical radiation for thermally induced retinal injury.
MedLine Citation:
PMID:  21399437     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Exposure limits (ELs) for laser and optical broadband radiation that are derived to protect the retina from adverse thermally-induced effects vary as a function of wavelength, exposure duration, and retinal irradiance diameter (spot size) expressed as the angular subtense α. A review of ex vivo injury threshold data shows that, in the ns regime, the microcavitation-induced damage mechanism results in retinal injury thresholds below thermal denaturation-induced thresholds. This appears to be the reason that the injury thresholds for retinal spot sizes of about 80 μm (α = 6 mrad) and pulse durations of about 5 ns in the green wavelength range are very close to current ELs, calling for a reduction of the EL in the ns regime. The ELs, expressed in terms of retinal radiant exposure or radiance dose, currently exhibit a 1/α dependence up to a retinal spot size of 100 mrad, referred to as αmax. For α ≥ αmax, the EL is a constant retinal radiant exposure (no α dependence) for any given exposure duration. Recent ex vivo, computer model, and non-human primate in vivo threshold data provide a more complete assessment of the retinal irradiance diameter dependence for a wide range of exposure durations. The transition of the 1/α dependence to a constant retinal radiant exposure (or constant radiance dose) is not a constant αmax but varies as a function of the exposure duration. The value of αmax of 100 mrad reflects the spot size dependence of the injury thresholds only for longer duration exposures. The injury threshold data suggest that αmax could increase as a function of the exposure duration, starting in the range of 5 mrad in the μs regime, which would increase the EL for pulsed exposure and extended sources by up to a factor of 20, while still assuring an appropriate reduction factor between the injury threshold and the exposure limit.
Authors:
Karl Schulmeister; Bruce E Stuck; David J Lund; David H Sliney
Related Documents :
9445467 - Interband electronic excitation-assisted atomic-scale restructuring of metal surfaces b...
8137167 - Calbindin d-28k as a marker for the associative cortical territory of the striatum in m...
2735847 - Dynamic behavior of the middle ear based on sweep frequency tympanometry.
7421607 - Application of the barr and stround gn5 densitometer for description of the chromatin s...
20636337 - Characterization of particulate matter size distributions and indoor concentrations fro...
15331157 - Intra-limb segmental influences on random-like movements in humans.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Health physics     Volume:  100     ISSN:  1538-5159     ISO Abbreviation:  Health Phys     Publication Date:  2011 Feb 
Date Detail:
Created Date:  2011-03-14     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  2985093R     Medline TA:  Health Phys     Country:  United States    
Other Details:
Languages:  eng     Pagination:  210-20     Citation Subset:  IM    
Affiliation:
* Seibersdorf Labor GmbH, A-2444 Seibersdorf, Austria; † U.S. Army Institute of Surgical Research, Fort Sam Houston, TX 78234-6315; ‡ Consulting Medical Biophysicist, Fallston, MD.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Determination of 239pu airborne concentration alpha correction factor for a zinc sulfide detector vi...
Next Document:  Assessment of Beta particle flux from surface contamination as a relative indicator for radionuclide...