Reversed-phase high-performance liquid chromatographic separation of diastereomers of (R,S)-mexiletine prepared by microwave irradiation with four new chiral derivatizing reagents based on trichloro-s-triazine having amino acids as chiral auxiliaries and 10 others having amino acid amides.
MedLine Citation:
PMID:  21035811     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
A new series of chiral derivatizing reagents (CDRs) consisting of four dichloro-s-triazine reagents was synthesized by nucleophilic substitution of one chlorine atom in trichloro-s-triazine with amino acids, namely L-Leu, D-Phg, L-Val and L-Ala as chiral auxiliaries. Two other sets of CDRs consisting of four dichloro-s-triazine (DCT) and six monochloro-s-triazine (MCT) reagents were also prepared by nucleophilic substitution of chlorine atom(s) with different amino acid amides as chiral auxiliaries in trichloro-s-triazine and its 6-methoxy derivative, respectively. These 14 CDRs were used for the synthesis of diastereomers of (R,S)-mexiletine under microwave irradiation (i.e. 60s and 90 s at 85% power (of 800 W) using DCT and MCT reagents, respectively), which were resolved by reversed-phase high-performance liquid chromatography using C18 column and gradient eluting mixtures of methanol with aqueous trifluoroacetic acid (TFA) with UV detection at 230 nm. The resolution (R(s)), difference between retention times of resolved diastereomers (Δt) and retention factors (k) obtained for the three sets of diastereomers were compared among themselves and among the three groups. Explanations have been offered for longer retention times and better resolution of diastereomers prepared with DCT reagents in comparison of their MCT counterparts and, for the influence of hydrophobicity of the side chain R of the amino acid in the CDRs on retention times and resolution. The newly synthesized CDRs were observed to be superior as compared to their amide counterparts in terms of providing better resolution and cost effectiveness. The method was validated for limit of detection, linearity, accuracy and precision.
Authors:
Ravi Bhushan; Shuchi Dixit
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2010-10-28
Journal Detail:
Title:  Journal of chromatography. A     Volume:  1217     ISSN:  1873-3778     ISO Abbreviation:  J Chromatogr A     Publication Date:  2010 Dec 
Date Detail:
Created Date:  2010-11-15     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9318488     Medline TA:  J Chromatogr A     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  7669-76     Citation Subset:  IM    
Copyright Information:
Copyright © 2010 Elsevier B.V. All rights reserved.
Affiliation:
Department of Chemistry, Indian Institute of Technology Roorkee, Roorkee 247667, India. rbushfcy@iitr.ernet.in
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Development of a solid-phase extraction with capillary liquid chromatography tandem mass spectrometr...
Next Document:  Optimisation of a dispersive liquid-liquid microextraction method for the simultaneous determination...