Document Detail


Reproducibility of left ventricular volume measurements at rest and during bicycle exercise in patients with congestive heart failure: a combined radionuclide and haemodynamic study.
MedLine Citation:
PMID:  8843118     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A series of 14 patients with heart failure due to coronary artery disease and impaired left ventricular function underwent radionuclide ventriculography with simultaneous thermodilution measurement of cardiac output by pulmonary artery catheter on two occasions (m1, m2) separated by 6 weeks in order to determine the reproducibility of haemodynamic and left ventricular volume measurements at rest and during supine bicycle exercise. The patients were in NYHA grade II or III and had baseline left ventricular ejection fractions below 40%. Derived haemodynamic variables were calculated from the thermodilution cardiac output and from the radionuclide ejection fraction as follows: stroke volume = thermodilution cardiac output/heart rate; left ventricular end-diastolic volume = stroke volume/ejection fraction; left ventricular end-systolic volume = end-diastolic volume - stroke volume. The percentage difference (PD) between each pair of data (m1, m2) was calculated using the following formula: PD = 100% x (m2-m1)/m1. The data showed that reproducible measurements of left ventricular volume can be obtained at rest and during exercise. The mean (+/- S.D.) PD values for end-systolic volume and end-diastolic volume at rest were - 0.1 +/- 17% and - 0.2 +/- 13%, respectively. The mean PD values for end-systolic volume and end-diastolic volume during exercise were - 0.3 +/- 19% and - 0.7 +/- 15%, respectively. By contrast, the reproducibility of the pulmonary capillary wedge pressure measurements was poor, as reflected by a PD value of 14 +/- 51% for exercise pulmonary capillary pressure. Combining radionuclide ventriculography and the thermodilution measurement of cardiac output is useful for measuring left ventricular volume at rest and during exercise in patients with heart failure. This minimally invasive technique allows for a comprehensive assessment of left ventricular performance and appears to be particularly suited for assessing the effects of therapeutic interventions aimed at minimizing the progressive left ventricular enlargement in heart failure.
Authors:
S Wieshammer; M Hetzel; J Hetzel; E Henze; M Clausen; V Hombach
Related Documents :
2311438 - A comparison of systolic time intervals measured by impedance cardiography and carotid ...
2912598 - End-systolic pressure as a balance between opposing effects of ejection.
8143308 - Conductance catheter measurements of left ventricular volume in the intact dog: paralle...
857628 - Systolic and diastolic ventricular function in cardiac amyloidosis. studies in six case...
1695308 - Calcium antagonists as first-line antihypertensive agents: a placebo-controlled, compar...
8937388 - Ethnic differences in blood pressure: findings from the fletcher challenge-auckland uni...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Nuclear medicine communications     Volume:  17     ISSN:  0143-3636     ISO Abbreviation:  Nucl Med Commun     Publication Date:  1996 Jul 
Date Detail:
Created Date:  1997-01-08     Completed Date:  1997-01-08     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  8201017     Medline TA:  Nucl Med Commun     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  591-5     Citation Subset:  IM    
Affiliation:
Department of Internal Medicine II, University of Ulm, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Cardiac Output
Exercise Test
Heart Failure / physiopathology*,  radionuclide imaging*
Heart Rate
Hemodynamics
Humans
Middle Aged
Radionuclide Ventriculography
Reproducibility of Results
Stroke Volume
Thermodilution
Ventricular Function, Left*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  240 degrees: why not?
Next Document:  Inter-observer agreement in the reporting of 99Tcm-DMSA renal studies.