Reproducibility and instrument validity of a new ultrasonography-based system for measuring cervical spine kinematics.
MedLine Citation:
PMID:  10946098     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To report instrument validity of CMS 70P, a new ultrasonography-based system for spatial kinematic analysis of the spine and its application in studying the reproducibility of cervical motion findings in healthy subjects. BACKGROUND: Reproducibility of cervical motion has been investigated using various instruments and consisting in most cases of short test-retest time intervals of between minutes to days. METHODS: Performance of the instrument was validated against a digital inclinometer, at ranges of motion compatible with actual cervical motion. To study reproducibility, 25 healthy individuals, 22 women and 3 men aged 26-48 were tested twice within an average time interval of 3.3 weeks. Performed in the seated position and at a self-determined pace, cervical motion was defined in terms of head motion relative to a sternal (reference) system, in all six primary motions: flexion, extension, right rotation, left rotation, right lateral flexion and left lateral flexion. RESULTS: The system exhibited excellent agreement with the digital inclinometer, establishing its instrument validity for testing cervical motion. No significant differences were indicated between the test and retest for both the net maximal displacements and average velocities. The correlation coefficients for the single plane motions (e.g. flexion+extension) were higher than those derived for the primary motions, and ranged between 0.78 (sagittal plane) and 0.88 (frontal plane). The magnitude of the standard error of the measurement reflected the same trend with the lowest value recorded for the frontal plane. The self-selected velocity at which these motions were performed was similar in the frontal and saggital planes but was significantly higher for the transverse plane (rotations). CONCLUSIONS: This study indicates that spanned over time intervals that are measured in weeks, cervical motion findings derived from the CMS 70P are well reproducible. Findings also imply the need for a more stringent control of subject positioning and stabilization. RELEVANCE: Reduction of range of motion and average is typically observed in various pathologies of the cervical spine and is regarded, together with pain, as a major impairment. Therefore, valid assessment of cervical motion which is essential for follow-up and treatment outcome strongly depends on reproducibility of the findings. This study indicates that acceptable reproducibility is maintained over periods of time which are clinically meaningful using the system described herewith.
Authors:
Z Dvir; T Prushansky
Related Documents :
2922638 - Measurement of human lumbar spine ligaments during loaded and unloaded motion.
19674918 - Three-dimensional spine kinematics during multidirectional, target-directed trunk movem...
18552678 - Transferring patients with thoracolumbar spinal instability: are there alternatives to ...
15863348 - The kinematics and intra- and inter-therapist consistencies of lower cervical rotationa...
22216118 - Response of a specialist bat to the loss of a critical resource.
19335408 - Real-time monitoring of force response measured in mechanically stimulated tissue-engin...
Publication Detail:
Type:  Clinical Trial; Journal Article    
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  15     ISSN:  0268-0033     ISO Abbreviation:  Clin Biomech (Bristol, Avon)     Publication Date:  2000 Nov 
Date Detail:
Created Date:  2000-10-18     Completed Date:  2000-10-18     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  658-64     Citation Subset:  IM; S    
Affiliation:
Department of Physical Therapy, Sackler Faculty of Medicine, Tel Aviv University, 69978 Ramat Aviv, Israel. zdvir@post.tau.ac.il
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Biomechanics
Calibration
Cervical Vertebrae / physiology*,  ultrasonography*
Female
Humans
Male
Middle Aged
Neck / physiology,  ultrasonography
Range of Motion, Articular / physiology*
Reference Values
Reproducibility of Results