Document Detail


Reproducibility of fetal renal pelvis volume assessed by three-dimensional ultrasonography with two different measurement techniques.
MedLine Citation:
PMID:  23325421     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
PURPOSE.: To evaluate reproducibility of fetal renal pelvis volume as assessed by the Virtual Organ Computer Aided AnaLysis (VOCAL) imaging program and by Automatic Volume Calculation (SonoAVC). In addition, the intra- and interobserver reliability of fetal renal pelvis volume measurements with SonoAVC were established. METHODS.: In this study, the fetal renal pelvis volume was measured using 3D ultrasonography in 76 kidneys of 66 fetuses with renal pelvis dilatation in the second or third trimester of pregnancy. After volume acquisition by one observer, the reproducibility of volume calculation was assessed using VOCAL imaging program and SonoAVC by two observers. Intra- and interobserver reproducibility was evaluated by calculating intraclass correlation coefficients (ICC), coefficient of variation (CV) and repeatability coefficient (r). Bland-Altman plots were generated to explore agreement. RESULTS.: A high degree of reproducibility was observed between VOCAL and SonoAVC, ICC of 0.989; 95% CI 0.983-0.993, respectively. Intraobserver reproducibility of volume measurements performed by SonoAVC demonstrated a high degree of reliability with ICC of 0.995 (95% CI 0.993-0.997), CV 6.05% and r of 0.75. The interobserver reproducibility with ICC of 0.995 (95% CI 0.992-0.997), CV 10.14% and r 1.21 was also indicative of good reliability. CONCLUSION.: Volume measurements of fetal renal pelvis performed by SonoAVC renders reproducible measurements in comparison with the VOCAL imaging program. There is no significant difference between VOCAL imaging program and SonoAVC. The intra- and interobserver reliability of the fetal renal pelvis measurements made by SonoAVC were considered to be very good. SonoAVC, however, needs post processing in the majority of cases but is less time consuming than VOCAL. © 2013 Wiley Periodicals, Inc. J Clin Ultrasound, 2013.
Authors:
L K Duin; C Willekes; M Vossen; J Offermans; J G Nijhuis
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-17
Journal Detail:
Title:  Journal of clinical ultrasound : JCU     Volume:  -     ISSN:  1097-0096     ISO Abbreviation:  J Clin Ultrasound     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-17     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401663     Medline TA:  J Clin Ultrasound     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2013 Wiley Periodicals, Inc.
Affiliation:
Department of Obstetrics and Gynecology of the Maastricht University Medical Centre, The Netherlands. L.duin@mmc.nl.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An overview of the highly pathogenic H5N1 influenza virus.
Next Document:  Differentiation between balanitis and carcinoma in situ using reflectance confocal microscopy.