Reproducibility of electromyographic patterns in stretch-shortening type contractions.
MedLine Citation:
PMID:  2311598     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Within a set of repeated measurements, 12 male subjects performed the following types of muscle contraction: (1) running at constant velocity (12 km.h-1); (2) one-leg hopping at the frequency preferred; (3) both-legs hopping at the frequency preferred; (4) drop jumps from a height of 0.40 m. The surface electromyographs (EMG) from the left and right legs were recorded, together with the averaged signals from vertical ground reaction forces and angular displacement of the ankle joint. Reliability coefficients for the day to day and the week to week comparison were calculated. In addition, on any one test day the positions of the electrodes were systematically changed. The analysis of various EMG parameters (integrated-EMG) revealed high coefficients for both comparisons as well as for the total set of measurements. Qualitative comparisons of the EMG showed a high reproducibility of the shape of the patterns. If the relative position of the electrodes with respect to the belly of the muscle is changed, the amplitudes of the EMG recordings are markedly reduced. It is concluded that surface EMG is a reliable method for studies of the neuromuscular system. On the basis of the data presented, it is suggested that the term "reliability" should be replaced by the term "reproducibility" in order to cover both the aspect of the relative stability plus the aspects of linear changes and the scattering of the data in repeated measurements.
Authors:
A Gollhofer; G A Horstmann; D Schmidtbleicher; D Schönthal
Related Documents :
12116298 - Story of electromyography equipment.
17304528 - Postural and respiratory functions of the pelvic floor muscles.
2019368 - Reproducibility of long-term ambulatory esophageal combined ph/manometry.
11562918 - Variability of frequency and phase between antagonistic muscle pairs in pathological hu...
2248828 - Effect of motion artefact on pulse oximeters: evaluation of four instruments and finger...
3253628 - Detection of low spatial frequencies: a single filter or multiple filters?
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  European journal of applied physiology and occupational physiology     Volume:  60     ISSN:  0301-5548     ISO Abbreviation:  Eur J Appl Physiol Occup Physiol     Publication Date:  1990  
Date Detail:
Created Date:  1990-04-17     Completed Date:  1990-04-17     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0410266     Medline TA:  Eur J Appl Physiol Occup Physiol     Country:  GERMANY, WEST    
Other Details:
Languages:  eng     Pagination:  7-14     Citation Subset:  IM    
Affiliation:
Institut für Sport und Sportwissenschaft, Universität Freiburg, Federal Republic of Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Electromyography* / methods
Humans
Male
Muscle Contraction*
Reproducibility of Results
Time Factors

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Physiological effects of inspiratory resistance on progressive aerobic work.
Next Document:  Muscle hypertrophy and fast fiber type conversions in heavy resistance-trained women.