Document Detail


Reproducibility of brachial ultrasonography and flow-mediated dilatation (FMD) for assessing endothelial function.
MedLine Citation:
PMID:  9483230     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: High-resolution brachial artery ultrasonography is used to study vasodilator response induced by physiologic reactive hyperaemia. We examined the reproducibility of measuring flow-mediated dilatation (FMD) on two occasions. AIMS: To determine the degree of variability of this technique in our vascular laboratory for the design of clinical research studies. METHODS: Nineteen subjects were studied on two separate occasions using an Acuson 128 ultrasound device and a 7.0 MHz linear array transducer. Reactive hyperaemia was induced in the brachial artery by inflation and release of a blood pressure cuff. Nitrate-induced dilatation was assessed in 11 of the 19 subjects. Measurements were made by two observers blinded to subject details. RESULTS: The 11 subjects given sublingual GTN during the first ultrasound study had a mean nitrate-induced dilatation of 20.7% (sd 9.6). The mean vessel diameter of 3.78 mm (sd 0.7) at rest and 3.89 mm (sd 0.7) during reactive hyperaemia yielded a mean FMD of only 3.0% (sd 2.7). The mean difference in FMD within-observers was 0.13% (sd 2.07), between-observers 0.06% (sd 2.17) and between-studies was 0.57% (sd 6.83). CONCLUSIONS: The reproducibility of FMD measured by brachial artery ultrasound was poor and likely to render the measurements inaccurate for clinical research in our hands. Between-study variation contributed the largest proportion of total study variability. We suggest that investigators using this technique conduct their own careful reproducibility studies in order to avoid the misinterpretation of 'negative' studies.
Authors:
K L Hardie; S Kinlay; D B Hardy; J Wlodarczyk; J S Silberberg; P J Fletcher
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Australian and New Zealand journal of medicine     Volume:  27     ISSN:  0004-8291     ISO Abbreviation:  Aust N Z J Med     Publication Date:  1997 Dec 
Date Detail:
Created Date:  1998-04-09     Completed Date:  1998-04-09     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  1264322     Medline TA:  Aust N Z J Med     Country:  AUSTRALIA    
Other Details:
Languages:  eng     Pagination:  649-52     Citation Subset:  IM    
Affiliation:
University of Newcastle, NSW, Australia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Brachial Artery / ultrasonography*
Endothelium, Vascular / physiology*
Female
Humans
Male
Middle Aged
Observer Variation
Regional Blood Flow
Reproducibility of Results
Vasodilation / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Dendritic antigen-presenting cells of the distal section of the female reproductive tract in normal,...
Next Document:  Radiofrequency ablation for cure of atrial flutter.