Reliability of measurement of muscle fiber conduction velocity using surface EMG.
MedLine Citation:
PMID:  10354908     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Cross-correlating two surface EMG signals detected at two different locations along the path of flow of action potential enables the measurement of the muscle fiber average conduction velocity in those active motor units monitored by the electrodes. The position of the peak of the cross-correlation function is the time delay between the two signals and hence the velocity may be deduced. The estimated velocity using this technique has been observed previously to depend on the location of the electrodes on the muscle surface. Different locations produced different estimates. In this paper we present a measurement system, analyze its inherent inaccuracies and use it for the purpose of investigating the reliability of measurement of conduction velocity from surface EMG. This system utilizes EMG signals detected at a number of locations on the biceps brachii, when under light tension, to look for any pattern of variations of velocity as a function of location and time. It consists of a multi-electrode unit and a set of eight parallel on-line correlators. The electrode unit and the parallel correlators ensure that these measurements are carried out under the same physical and physiological conditions of the muscle. Further, the same detected signals are used in different measurement configurations to try to understand the reasons behind the observed variations in the estimated velocity. The results obtained seem to suggest that there will always be an unpredictable random component superimposed on the estimated velocity, giving rise to differences between estimates at different locations and differences in estimates with time at the same location. Many factors contribute to this random component, such as the non-homogeneous medium between the muscle fibers and the electrodes, the non-parallel geometry and non-uniform conduction velocity of the fibers, and the physical and physiological conditions of the muscle. While it is not possible to remove this random component completely from the measurement, the user must be aware of its presence and how to reduce its effects.
Authors:
M I Harba; L Y Teng
Related Documents :
3411508 - Changes in perceived heaviness and motor commands produced by cutaneous reflexes in man.
4065268 - Reflex responses of the human jaw-closing system depend on the locus of intraoral mecha...
17304528 - Postural and respiratory functions of the pelvic floor muscles.
1640378 - Biomechanical analysis of wheelchair propulsion for various seating positions.
20718218 - Fluoride-releasing orthodontic adhesives and topical fluoride effect on enamel caries f...
21913658 - Nir light induced deformation of crosslinked liquid crystal polymers using upconversion...
Publication Detail:
Type:  Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering     Volume:  9     ISSN:  0921-3775     ISO Abbreviation:  Front Med Biol Eng     Publication Date:  1999  
Date Detail:
Created Date:  1999-07-20     Completed Date:  1999-07-20     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  9011464     Medline TA:  Front Med Biol Eng     Country:  NETHERLANDS    
Other Details:
Languages:  eng     Pagination:  31-47     Citation Subset:  IM    
Affiliation:
Universiti Sains Malaysia, Perak, Malaysia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Action Potentials / physiology*
Adult
Algorithms
Arm
Electrodes
Electromyography / instrumentation,  methods*
Humans
Muscle Contraction / physiology
Muscle Fibers, Skeletal / physiology*
Neural Conduction
Reaction Time
Reproducibility of Results

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Suitable location and optimum bladder width for the occluding cuff used for indirect arterial blood ...
Next Document:  New on-line methods for analysis of walking foot pressures in diabetic neuropathy.