Abstract/OtherAbstract:
This study determined the intratester and intertester variability and reliability of goniometric measurements taken by four physical therapists on upper and lower extremity motions of normal male subjects. The same subjects were measured once weekly for four weeks by testers with varied experience in goniometry. Data were analyzed by analyses of variance with repeated measures. Intratester variation for all measurements was less than intertester variation. Further, intertester variation was less for the three upper extremity motions than for those of the lower extremity. These findings indicate the necessity for using the same tester when effects of treatment are evaluated. When the same tester measures the same movement, increases in joint motion of at least three to four degrees determine improvement for either the upper or lower extremity. When more than one tester, however, measures the same movement, increases in joint motion should exceed five degrees for the upper extremity and six degrees for the lower extremity to determine improvement.
Authors:
D C Boone; S P Azen; C M Lin; C Spence; C Baron; L Lee
Related Documents :
7774544 - How the horse moves: 1. significance of graphical representations of equine forelimb ki...
12628574 - Ranking systems for evaluation of joint and joint motion stressfulness based on perceiv...
8515024 - Motion after metacarpophalangeal joint reconstruction in rheumatoid disease.
19225174 - The synergistic organization of muscle recruitment constrains visuomotor adaptation.
2756054 - Temporal integration and reaction times in human smell.
12367744 - Measurement of angular velocity in the perception of rotation.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Physical therapy     Volume:  58     ISSN:  0031-9023     ISO Abbreviation:  Phys Ther     Publication Date:  1978 Nov 
Date Detail:
Created Date:  1978-12-27     Completed Date:  1978-12-27     Revised Date:  2010-05-17    
Medline Journal Info:
Nlm Unique ID:  0022623     Medline TA:  Phys Ther     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1355-60     Citation Subset:  AIM; IM; S    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Analysis of Variance
Arm / physiology
Extremities / physiology*
Humans
Joints / physiology*
Leg / physiology
Male
Middle Aged
Movement*
Weights and Measures