The Reliability and Accuracy of a Noncontact Electrocardiograph System for Screening Purposes.
MedLine Citation:
PMID:  22104072     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Background:Electrocardiography (ECG) requires the application of electrodes to the skin and often necessitates undressing. Capacitively coupled electrodes embedded in a normal chair would be a rational alternative for ECG screening. We evaluated the reliability and accuracy of ECG electrodes imbedded in a chair cushion.Methods:Two independent clinicians compared ECG recordings obtained using skin electrodes with recordings obtained using capacitively coupled electrodes that were embedded in a chair cushion in an anesthesiology premedication room, a cardiology outpatient ward, and a cardiology day ward. We analyzed the data to compare the sensitivity and specificity for the diagnosis of cardiac arrhythmias.Results:ECG recordings were obtained from 107 patients. Heart rate was accurately measured using the capacitively coupled electrodes, but motion artifacts made the identification of P and T waves unreliable. Signal quality was poor for patients with low body weight, patients wearing clothing containing mixed fibers, and patients wearing sweaty shirts.Conclusions:Heart rate was accurately measured, and some cardiac arrhythmias were correctly diagnosed using capacitive ECG electrodes. Capacitive electrodes embedded into an examination chair are a promising tool for preoperative screening. Improved artifact reduction algorithms are needed before capacitive electrodes will replace skin electrodes.
Authors:
Michael Czaplik; Benjamin Eilebrecht; Rafael Walocha; Marian Walter; Patrick Schauerte; Steffen Leonhardt; Rolf Rossaint
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-11-21
Journal Detail:
Title:  Anesthesia and analgesia     Volume:  -     ISSN:  1526-7598     ISO Abbreviation:  -     Publication Date:  2011 Nov 
Date Detail:
Created Date:  2011-11-22     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  1310650     Medline TA:  Anesth Analg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
From the *Department of Anesthesiology, University Hospital, RWTH Aachen, Aachen, Germany;
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A Rare Anatomical Variation of the Brachial Plexus: Single Cord Anomaly.
Next Document:  Oxytocin Inhibits the Membrane Depolarization-Induced Increase in Intracellular Calcium in Capsaicin...