| Relationship between pacemaker fibrillation thresholds and electrode area. | |
| | |
MedLine Citation:
|
PMID: 1143115 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
Energy thresholds for electrical pacing of the heart are lower with small electrodes than with large. Because pacing of the heart during the vulnerable period may produce ventricular fibrillation, it is also pertinent to know if fibrillation threshold is affected by the electrode size. Electrodes of different surface area but of the same material were implanted in 40 dogs and the pacing thresholds were recorded. Ventricular fibrillation was electrically induced by discharging a 2-msec d.c. cathodal pulse of progressively increasing energy into the vulnerable period. It was found that small electrodes required more energy to produce ventricular fibrillation than large electrodes, and the ratio of fibrillation to stimulation threshold was higher for the small-surface-area electrode. The difference between the thresholds and ratios obtained with the various electrodes was statistically significant. A similar experiment was performed in animals with chronically implanted electrodes, producing comparable results. The results indicate that, in regard to pacing and fibrillation thresholds, small electrodes are preferable to large. |
| | |
Authors:
|
P Chen; G H Myers; V Parsonnet; K Chatterjee; P Katz |
Related Documents
:
|
23441005 - Early and prolonged ecg alterations resembling a myocardial injury after severe amitrip... 17383215 - Comparative study between dd-hmm and rbf in ventricular tachycardia and ventricular fib... 8597885 - Cardiac release of histamine after ventricular fibrillation and defibrillation during i... 4074595 - Efficacy of an implanted automatic defibrillator which had induced atrial fibrillation. 23732925 - Cathepsin b inhibition attenuates cardiac dysfunction and remodeling following myocardi... 15003105 - Closed mitral commissurotomy following pericardial strip posterior mitral annuloplasty. |
Publication Detail:
|
Type: Comparative Study; Journal Article |
Journal Detail:
|
Title: Medical instrumentation Volume: 9 ISSN: 0090-6689 ISO Abbreviation: Med Instrum Publication Date: 1975 Jul-Aug |
Date Detail:
|
Created Date: 1975-10-10 Completed Date: 1975-10-10 Revised Date: 2006-11-15 |
Medline Journal Info:
|
Nlm Unique ID: 0361136 Medline TA: Med Instrum Country: UNITED STATES |
Other Details:
|
Languages: eng Pagination: 165-70 Citation Subset: IM |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Animals Differential Threshold Dogs Electrodes, Implanted Pacemaker, Artificial* / adverse effects, instrumentation Ventricular Fibrillation / etiology* |