Relationship between mouth and esophageal pressures in different body postures.
MedLine Citation:
PMID:  6652289     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Static voluntary efforts, both inspiratory and expiratory (executed with the glottis open against a closed airway) are commonly utilized for the evaluation of correct esophageal balloon positioning for indirect pleural pressure measurement. Agreement between delta Pm (change in mouth pressure) and delta Pes (change in esophageal pressure) indicates the valid indirect determination of pleural pressure. Measurements of delta Pes are more commonly made with the thorax in the upright position, and some investigators have reservations about determinations carried out in the supine position. In the present investigation, the airway shutter occlusion test as well as Müller's maneuver were applied to patients sitting in a plethysmographic box to determine the validity of delta Pes in several body positions. Measurements were made on 8 patients sitting with the thorax in the vertical (90 degrees) position and at angles of 45 degrees, 0 degree and -10 degrees. Thoracic gas volume was also determined at each angle studied. The esophageal balloon was shown to need frequent repositioning when body position was changed. With proper care, valid delta Pes measurements could be made in all positions studied. A plot of the delta Pes/delta POm ratio showed values closer to one for the "occlusion test" than for Müller's maneuver. Phase differences between delta Pes and delta Pm were very small in different body positions. Cardiac artifacts in esophageal measurements were more pronounced in the horizontal and -10 degrees positions. The "occlusion test" is particularly useful for clinical application because it does not require patient cooperation and is a very simple technique for evaluating correct esophageal catheter placement.
Authors:
A Fonseca-Costa; A E Nardi
Related Documents :
9322639 - A comparison of ultrasonographically detected cervical changes in response to transfund...
17010639 - Development of leptin antagonists and their potential use in experimental biology and m...
1496149 - Effects of position and mattress overlay on sacral and heel pressures in a clinical pop...
6758179 - Comparison of salbutamol given by intermittent positive-pressure breathing and pressure...
17371569 - A simple method for evaluation of tongue position.
21587159 - Pressure controlled ventilation to induce acute lung injury in mice.
22588209 - Validation of the isovolumetric relaxation time for the estimation of pulmonary systoli...
18307439 - Left atrial volume is associated with inflammation and atherosclerosis in patients with...
25019789 - Capillary adhesion at the nanometer scale.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Brazilian journal of medical and biological research = Revista brasileira de pesquisas médicas e biológicas / Sociedade Brasileira de Biofísica ... [et al.]     Volume:  16     ISSN:  0100-879X     ISO Abbreviation:  Braz. J. Med. Biol. Res.     Publication Date:  1983 Jul 
Date Detail:
Created Date:  1984-02-14     Completed Date:  1984-02-14     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8112917     Medline TA:  Braz J Med Biol Res     Country:  BRAZIL    
Other Details:
Languages:  eng     Pagination:  119-25     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Electrocardiography
Esophagus / physiology*
Humans
Lung / physiology*
Male
Mouth / physiology*
Plethysmography
Posture*
Pressure
Respiration
Respiratory Function Tests*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Propranolol and hyperthyroidism: sequential changes in serum iodothyronine (T4, T3, rT3) concentrati...
Next Document:  An inexpensive event recorder for continuous behavioral recording.