Document Detail


Relationship between intrathoracic pressure and hemodynamics during cardiopulmonary resuscitation in a porcine model of prolonged cardiac arrest.
MedLine Citation:
PMID:  23075711     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
BACKGROUND: The influences of intrathoracic pressure (ITP) to hemodynamic and respiratory parameters during cardiopulmonary resuscitation (CPR) are confusing. In this research, we investigated the phasic changes of ITP during CPR and reveal the relationships among the hemodynamics, respiratory parameters, and ITP.
METHODS: After 8 minutes of untreated ventricular fibrillation, which was induced in twenty intubated male domestic pigs, 12 minutes of 30: 2 CPR was performed. Continuous respiratory variables, hemodynamics, ITP and blood gas analysis were measured during CPR. After that, defibrillation was done and prognostic indicators after CPR was recorded.
RESULTS: Average ITP at baseline was -(14.1 ± 1.6) mmHg (1 mmHg = 0.133 kPa). When gasping inspirations were going on, it decreased sharply to near -50 mmHg. ITP fluctuated up and down quickly from near -20 mmHg to 20 mmHg when compressions were performed. These phasic changes became mild as the CPR was performed, the contrast of high and low ITP decreased to (12.95 ± 2.91) mmHg at the end of 12 minutes of CPR. Total alveolus minute volume decreased too, because of the decrease of compression and gasp related ventilations. Curve correlation was found between the tidal volume of compression and ITP: ITP = 607.33/(1 + 3134 × e(-0.58 × TV)), (e: natural constant, R(2) = 0.895). Negative correlations were found between the right atrial diastolic pressure and ITP (r = -0.753, P < 0.01); and positive correlations were found between the coronary perfusion pressure and ITP (r = 0.626, P < 0.01).
CONCLUSIONS: ITP is one of the key factors which can influence the prognosis of CPR. Correlations were found between the changes of ITP and the tidal volumes of compressions, right atrial diastolic pressure and coronary perfusion pressure during CPR. More positive ITP during compression and more negative during decompression were good to ventilation and perfusion.
Authors:
Shuo Wang; Chun-Sheng Li; Jun-Yuan Wu; Zhi-Jun Guo; Wei Yuan
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Chinese medical journal     Volume:  125     ISSN:  0366-6999     ISO Abbreviation:  Chin. Med. J.     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-18     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7513795     Medline TA:  Chin Med J (Engl)     Country:  China    
Other Details:
Languages:  eng     Pagination:  3606-11     Citation Subset:  IM    
Affiliation:
Department of Emergency Medicine, Beijing Chaoyang Hospital, Capital Medical University, Beijing 100020, China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Assessment of the effects of NS11394 and L-838417, ?2/3 subunit-selective GABA(A) [corrected] recept...
Next Document:  Evaluation of respiratory dysfunction in a pig model of severe acute dichlorvos poisoning.