Document Detail


Relation between pressure -and volume unloading during ramp testing in patients supported with a continuous-flow left ventricular assist device.
MedLine Citation:
PMID:  25485566     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Pulmonary capillary wedge pressure (PCWP) is the key to describing left ventricular (LV) unloading, however, the relation between pressure and the echocardiography-derived surrogate of LV volume (left ventricular end-diastolic diameter (LVEDD)) as a function of pump speed (RPM) in continuous-flow left ventricular assist device (CF-LVAD) patients is unknown. In this study the pressure-volume relationship as a function of RPM during ramp testing was investigated by simultaneously measuring PCWP by Swan-Ganz catheter and LVEDD by echocardiography. The ramp protocol started at usual pump setting (ramp-base) and then went from 8,000 RPM (ramp-low) increasing by 400 RPM/5 minutes until reaching 12,000 RPM or suction/arrhythmic event (ramp-high). The study was finalized by a 25-Watt exercise test at two ramp steps. Ten patients with ramp-base of 9,300 ± 241 RPM (at which 3/10 had aortic valve opening) were examined. At ramp-low, ramp-base and ramp-high PCWP was 20 ± 4, 14 ± 4 and 7 ± 3 mmHg (P<0.001 for all comparisons) and LVEDD 6.6 ± 1.0, 6.7 ± 0.9 and 5.5 ± 1.7 cm (P<0.05 for all comparisons but ramp-low vs. ramp-base). Correlation between PCWP -and LVEDD-slopes; R =0.53, (P=0.02). In conclusion, PCWP as a function of RPM is weakly correlated with changes in LVEDD. Thus LVEDD is not an accurate measure of unloading in CF-LVAD patients.
Authors:
Mette H Jung; Christian Hassager; Louise Balling; Stuart D Russell; Soeren Boesgaard; Finn Gustafsson
Related Documents :
11068856 - Increase in blood pressure with enhanced na+, k+ -atpase activity in stroke-prone spont...
5503886 - The effect of high oxygen tensions on the mechanical properties of rat lungs.
15319186 - Pressure activates rat pancreatic stellate cells.
25433536 - Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observ...
19455026 - Initial defibrillation versus initial chest compression in a 4-minute ventricular fibri...
22644526 - The stability of almond β-glucosidase during combined high pressure-thermal processing:...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2014-12-5
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  -     ISSN:  1538-943X     ISO Abbreviation:  ASAIO J.     Publication Date:  2014 Dec 
Date Detail:
Created Date:  2014-12-8     Completed Date:  -     Revised Date:  2014-12-9    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Hemodynamic Effects of Left Atrial or Left Ventricular Cannulation for Acute Circulatory Support in ...
Next Document:  Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in viv...