Document Detail


Regadenoson pharmacologic rubidium-82 PET: A comparison of quantitative perfusion and function to dipyridamole.
MedLine Citation:
PMID:  23188625     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: Dipyridamole is used for stress (82)rubidium chloride ((82)RbCl) PET because of its long hyperemic duration. Regadenoson has advantages of a fixed dose and favorable symptom profile, but its mean maximal hyperemia is only 2.3 minutes. To determine its suitability for (82)RbCl PET, we imaged subjects using a regadenoson protocol based on its hyperemic response and compared the images in the same subjects having dipyridamole PET. METHODS: In 32 subjects (23 M), we assessed visually by blinded interpretation and quantitatively compared summed stress and difference scores, total perfusion deficit (TPD), LVEF, LV volumes, and change in stress-rest function. Linear correlation and Bland-Altman analysis of the paired measurements were applied for evaluation of differences. Paired t test and Pearson's correlation were applied for testing of significance. RESULTS: The images were interpreted the same by visual assessment. Twenty-six (26) subjects had reversible defects; by quantitation the SSS was 12.9 ± 7.0 and 14.1 ± 6.4 (P = .23) and SDS was 7.0 ± 6.8 versus 7.6 ± 6.2 (P = .40) for dipyridamole and regadenoson, respectively. Six (6) subjects had <5% likelihood of CAD and were normal by both. All paired measurements showed a high positive correlation between regadenoson and dipyridamole; stress segmental perfusion Reg = 0.93Dip + 4.4, r = 0.88; TPD Reg = 0.94Dip + 0.41, r = 0.93; LVEF Reg = 0.92Dip + 4.7, r = 0.95; stress minus rest LVEF Reg = 0.87Dip - 0.99, r = 0.82. CONCLUSION: Regadenoson stress (82)RbCl PET perfusion defect and cardiac function measurements are visually and quantitatively equivalent to dipyridamole studies and can be obtained with the clinical advantages of regadenoson.
Authors:
S James Cullom; James A Case; Staci A Courter; A Iain McGhie; Timothy M Bateman
Related Documents :
2080355 - Interactive sonar-operated device for stereotactic and open surgery.
12759495 - A new blade for the bookwalter retractor system.
7207785 - Self-retaining retractor and handrest system for neurosurgery.
9924405 - Stereolithographic (sl) biomodelling in craniofacial surgery.
25205565 - A biocompatible "split luciferin" reaction and its application for non-invasive biolumi...
24334315 - A high resolution spect detector based on thin continuous lyso.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-11-28
Journal Detail:
Title:  Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology     Volume:  -     ISSN:  1532-6551     ISO Abbreviation:  J Nucl Cardiol     Publication Date:  2012 Nov 
Date Detail:
Created Date:  2012-11-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9423534     Medline TA:  J Nucl Cardiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Cardiovascular Imaging Technologies, LLC, 4320 Wornall Road, Suite 55, Kansas City, MO, 64111, USA, medigent@kc.rr.com.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clinical value of stress-only Tc-99m SPECT imaging: Importance of attenuation correction.
Next Document:  A strategy of symptom-limited exercise with regadenoson-as-needed for stress myocardial perfusion im...