| Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. | |
| | |
MedLine Citation:
|
PMID: 18594097 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
We previously reported wear data at a minimum of two years following thirty-four total hip replacements with a Marathon cross-linked polyethylene liner and twenty-four replacements with a conventional (gamma-sterilized-in-air) Enduron polyethylene liner. In this current study, with sequential five-year radiographs, wear rates were determined with use of linear regression analysis. The Marathon polyethylene had average wear rates of 15.4 mm(3)/yr and 8.0 mm(3)/million cycles. The Enduron polyethylene had average wear rates of 55.5 mm(3)/yr and 29.9 mm(3)/million cycles. The adjusted volumetric wear rate of the Marathon polyethylene was 73% lower than that of the Enduron polyethylene (p = 0.001). Osteolysis developed in eight of the twenty-four hips with an Enduron liner but was not apparent in any hip with a Marathon liner. |
| | |
Authors:
|
Rudi G Bitsch; Travis Loidolt; Christian Heisel; Scott Ball; Thomas P Schmalzried |
Related Documents
:
|
12617317 - Environmental impact of noise levels in and around opencast bauxite mine. 9866367 - Changes in pulse rate among the civilian population during air-raid alerts in the city ... 22303317 - The extended nutrigenomics - understanding the interplay between the genomes of food, g... 12099457 - Estimates of the atmospheric deposition of sulfur and nitrogen species: clean air statu... 8600277 - Composition-based prediction of dielectric properties of foods. 1244997 - The hen's egg: independence of weight at oviposition and the sex of the chick. |
Publication Detail:
|
Type: Comparative Study; Journal Article |
Journal Detail:
|
Title: The Journal of bone and joint surgery. American volume Volume: 90 ISSN: 1535-1386 ISO Abbreviation: J Bone Joint Surg Am Publication Date: 2008 Jul |
Date Detail:
|
Created Date: 2008-07-02 Completed Date: 2008-07-16 Revised Date: 2010-10-25 |
Medline Journal Info:
|
Nlm Unique ID: 0014030 Medline TA: J Bone Joint Surg Am Country: United States |
Other Details:
|
Languages: eng Pagination: 1487-91 Citation Subset: AIM; IM |
Affiliation:
|
Stiftung Orthopädische Universitätsklinik, Schlierbacher Landstrasse 200A, 69118 Heidelberg, Germany. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Adult Aged Aged, 80 and over Arthroplasty, Replacement, Hip* Biocompatible Materials* Female Follow-Up Studies Humans Joint Prosthesis* Male Middle Aged Osteolysis / prevention & control* Polyethylene* Prosthesis Failure |
| Chemical | |
Reg. No./Substance:
|
0/Biocompatible Materials; 9002-88-4/Polyethylene |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Mortality following the diagnosis of a vertebral compression fracture in the Medicare population.