Document Detail


Reducing Patient Radiation Dose during CT-Guided Procedures: Demonstration in Spinal Injections for Pain.
MedLine Citation:
PMID:  21920858     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND AND PURPOSE:CT guidance may improve precision for diagnostic and therapeutic spinal injections, but it can increase patient radiation dose. This study examined the impact of reducing tube current on patient radiation exposure and the technical success for these procedures, by using axial acquisitions for short scan lengths and eliminating nonessential imaging.MATERIALS AND METHODS:Our institutional review board approved retrospective analysis of records from 100 consecutive outpatients undergoing spinal injections for pain before and after the CT protocol modification to reduce radiation dose. Data collected included patient age and sex, response to injection, number of sites and spinal levels treated, injection type, performing physician, CT acquisition method, number of imaging series, tube current, scan length, and DLP.RESULTS:Image contrast was reduced with the low-dose protocol, but this did not affect technical success or immediate pain relief. Mean DLP for all procedures decreased from 1458 ± 1022 to 199 ± 101 mGy · cm (P < .001). The range of radiologist-dependent DLP per procedure also was reduced significantly with the modified protocol. Selective nerve root blocks, lumbar injections, multiple injection sites, and the lack of prior imaging were each associated with a slightly higher DLP (<50 mGy · cm).CONCLUSIONS:Radiation to patients undergoing CT-guided spinal injections can be decreased significantly without affecting outcome by reducing tube current, using axial acquisitions for short scan lengths, and eliminating nonessential imaging guidance. These measures also decrease variability in radiation doses between different practitioners and should be useful for other CT-guided procedures in radiology.
Authors:
T M Shepherd; C P Hess; C T Chin; R Gould; W P Dillon
Related Documents :
20687188 - Synchrotron-based micro-ct imaging of the human lung acinus.
18229568 - New insights on copd imaging via ct and mri.
17293238 - Reduction of pulmonary compliance found with high-resolution computed tomography in irr...
18666218 - Monitoring infection and inflammation in murine models of cystic fibrosis with magnetic...
8192088 - Proton mr spectroscopy in patients with seizure disorders.
21761468 - Evaluation of axillary lymph nodes by diffusion-weighted mri using ultrasmall superpara...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-9-15
Journal Detail:
Title:  AJNR. American journal of neuroradiology     Volume:  -     ISSN:  1936-959X     ISO Abbreviation:  -     Publication Date:  2011 Sep 
Date Detail:
Created Date:  2011-9-16     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8003708     Medline TA:  AJNR Am J Neuroradiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Neuroradiology Division, Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Fractionated Radiation-Induced Acute Encephalopathy in a Young Rat Model: Cognitive Dysfunction and ...
Next Document:  Normal Sagittal and Coronal Suture Widths by Using CT Imaging.