Document Detail


Red cell microparticle enumeration: validation of a flow cytometric approach.
MedLine Citation:
PMID:  22236393     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Background and Objectives  There is growing interest in the clinical application of red blood cell (RBC) microparticle (MP) enumeration as they have been postulated to be effectors of coagulation and inflammation following transfusion and in sickle cell disease. No uniform approach in MP enumeration exists and a key limitation is the lack of an internal validation process. We present and validate a flow cytometric approach where an internal standard is utilized. Materials and Methods  Glycophorin A(+) Annexin V(+) events were enumerated using MPs isolated from RBC units or plasma samples obtained from volunteers. A mixture of absolute counting (7·6 μm) and calibration beads (0·5, 0·9 and 3 μm) at a fixed ratio was added to each sample. Results  RBC MPs were initially selected based upon a fluorescence threshold, and the 0·5- and 0·9-μm beads defined the upper and lower light scatter distribution of MPs. The ratio of 7·6:3-μm bead events was used as an internal standard to validate the precision of MP enumeration across samples (coefficient of variation = 2·5-7·2%) and remained constant in both platelet-rich plasma (PRP) and platelet-free plasma (PFP). RBC MP counts increased in both PRP and PFP obtained from whole blood stimulated with ionophore and increasing calcium concentrations, with PRP showing higher MP counts than PFP at every concentration studied. Conclusion  This method is a useful strategy to detect RBC MP counts across bio-samples provided that the flow cytometer can reliably discriminate the size of the calibration beads.
Authors:
Z Xiong; T B Oriss; J P Cavaretta; M R Rosengart; J S Lee
Related Documents :
21481913 - Determination of deployment specific chemical uptake rates for sdb-rpd empore disk usin...
21602473 - Epoxyeicosatrienoic acid-dependent cerebral vasodilation evoked by metabotropic glutama...
8002543 - Chest wall interrupter resistance in anesthetized paralyzed humans.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-1-11
Journal Detail:
Title:  Vox sanguinis     Volume:  -     ISSN:  1423-0410     ISO Abbreviation:  -     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-1-12     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0413606     Medline TA:  Vox Sang     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
© 2012 The Author(s). Vox Sanguinis © 2012 International Society of Blood Transfusion.
Affiliation:
Division of Pulmonary, Allergy, and Critical Care Medicine, Department of Medicine, University of Pittsburgh, Pittsburgh, PA, USA Division of Trauma Surgery, Department of Surgery, University of Pittsburgh, Pittsburgh, PA, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A two-session psychological intervention for siblings of pediatric cancer patients: a randomized con...
Next Document:  Copeptin in aneurysmal subarachnoid hemorrhage.