Document Detail


Recurrence of dislocation following total hip arthroplasty revision using dual mobility cups was rare in 180 hips followed over 7 years.
MedLine Citation:
PMID:  23144637     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Dual mobility (DM) cups of mobile polyethylene were introduced to prevent total hip arthroplasty (THA) dislocation, but no large series with this design to treat recurrent instability have been reported.
PURPOSE: Our retrospective investigation ascertained the efficiency of DM cups in correction of recurrent dislocation and assessed any adverse effects.
METHODS: One hundred eighty THAs with recurrent instability were revised to DM cups in 180 patients (mean age, 67.4 ± 11.7 years; range, 19 to 92 years). Thirty-one patients (17.2%) underwent at least one earlier THA revision, and 15 (10.3%) incurred non-union of the greater trochanter. Of the initial group in 2009, 145 patients had completed evaluations which included assessment of the Harris Hip Score and a radiographic assessment at a mean follow-up of 7.7 ± 2.2 years (range, 4 to 14 years). The rate of survival was calculated considering any reason for revision as failure.
RESULTS: At follow-up, Harris hip score was 83.9 ± 16.1 (range, 21 to 100). Dislocation of the large articulation occurred in seven hips (4.8%), and only two recurred (1.4%) (one requiring additional revision). In addition, two intra-prosthetic dislocations of the small articulation (1.4%) were observed and needed revision surgery. The large number of earlier surgeries and non-union of the greater trochanter were related to recurrent instability. Two cups (1.4%) showed signs of definite loosening; six (4.1%) presented signs of possible loosening. Twenty-nine hips manifested femoral or acetabular osteolysis (20%), but only three were severe. Eight-year survival rate considering revision for any reason was 92.6% (95% CI, 85.5-96.4%).
CONCLUSIONS: This series indicates that DM cups are a viable option to treat recurrent THA instability. Their design provides a low risk of recurrent instability without increasing mechanical complications.
Authors:
Patrice Mertl; Antoine Combes; Frédérique Leiber-Wackenheim; Michel Henri Fessy; Julien Girard; Henri Migaud
Related Documents :
23065487 - Rupture of jejunal varices treated with balloon-occluded retrograde transvenous obliter...
6147067 - Effects of three non-insight-oriented treatment methods on agoraphobic women suitable f...
8375837 - Compliance with clinic attendance by outpatients with schizophrenia.
12606177 - 1-year retention and social function after buprenorphine-assisted relapse prevention tr...
23558157 - Virological analysis of once-daily and twice-daily darunavir/ritonavir in the odin tria...
16358937 - Surgical revascularization and perioperative management in patients with non-st-elevati...
Publication Detail:
Type:  Journal Article     Date:  2012-09-19
Journal Detail:
Title:  HSS journal : the musculoskeletal journal of Hospital for Special Surgery     Volume:  8     ISSN:  1556-3324     ISO Abbreviation:  HSS J     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-11-12     Completed Date:  2012-11-13     Revised Date:  2013-05-30    
Medline Journal Info:
Nlm Unique ID:  101273938     Medline TA:  HSS J     Country:  United States    
Other Details:
Languages:  eng     Pagination:  251-6     Citation Subset:  -    
Affiliation:
Orthopaedics Department, University of Amiens, place Victor-Pauchet, 80054 Amiens, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A germline polymorphism of DNA polymerase beta induces genomic instability and cellular transformati...
Next Document:  The application of genetics methods to differentiation of three Lactobacillus species of human origi...