Real world experience with an indigenously manufactured stent Cobal C - A retrospective study.
MedLine Citation:
PMID:  25443606     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
BACKGROUND: Second generation bare metal stents made of cobalt chromium alloy are superior to first generation stain less steel stents. The thin struts are shown to reduce clinical and angiographic adverse outcomes.
OBJECTIVE: To study the long term clinical and angiographic outcomes in patients who underwent coronary angioplasty with an indigenously made cobalt chromium bare metal stents with thin strut Cobal+C™ (Relisys).
METHODS: A total of 268 consecutive patients who underwent coronary angioplasty with Cobal+C stents were studied retrospectively. Clinical follow up was done after a minimum period of nine months through telephonic interview and angiographic follow up was done in 80 patients chosen randomly. The end points analyzed included major adverse cardiac events (MACE) at nine months and the rate of binary restenosis at follow up angiogram done between 9 and 15 months post angioplasty.
RESULTS: Thirty four percent were diabetic and 33% had acute myocardial infarction. Females constituted 17%. Mean stent diameter was 2.88 ± 0.28 and mean stent length 18.8 ± 4.2. MACE at nine months was 4.5% with TLR 0.3%. The rate of binary restenosis was 21%. Patients with longer stent lengths and non-compliance with medications had significantly higher rates of binary restenosis.
CONCLUSIONS: The use of Relisys Cobal+C stents was associated with good long term clinical and angiographic outcomes as evidenced by low incidence of MACE and binary restenosis rates for a bare metal stent.
Authors:
B K S Sastry; Nirmal Kumar; Rajeev Menon; Anuj Kapadia; C Sridevi; G Surya Prakash; N Krishna Reddy; M Srinivasa Rao
Related Documents :
21643866 - Radiology-led follow-up system for ivc filters: effects on retrieval rates and times.
25175926 - Appendicectomy for clincally-suspected appendicitis is associated with fewer complicati...
25274226 - How do the residual fragments after swl affect the health-related quality of life? a cr...
21701526 - Strabismus following retinal detachment repair: a comparison between scleral buckling a...
9261626 - Endovascular diagnosis and treatment of profuse esophageal bleeding in patients with po...
17297276 - Ten trigger fingers in an adult man: a case report.
Publication Detail:
Type:  Journal Article     Date:  2014-09-18
Journal Detail:
Title:  Indian heart journal     Volume:  66     ISSN:  0019-4832     ISO Abbreviation:  Indian Heart J     Publication Date:    2014 Sep-Oct
Date Detail:
Created Date:  2014-12-02     Completed Date:  -     Revised Date:  2014-12-04    
Medline Journal Info:
Nlm Unique ID:  0374675     Medline TA:  Indian Heart J     Country:  India    
Other Details:
Languages:  eng     Pagination:  525-9     Citation Subset:  IM    
Copyright Information:
Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Risk scoring system to predict contrast induced nephropathy following percutaneous coronary interven...
Next Document:  Clopidogrel resistance: The way forward.