Document Detail


Reactive deposition of nano-films in deep polymeric microcavities.
MedLine Citation:
PMID:  23032697     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
We report the controlled diffusion of gas-phase high-reactivity chemical species into long polymeric microcavities to form glass-like, low-permeability barrier films on the interior surfaces of the microcavities. Reactive species created from fragmentation of O(2) and hexamethyldisiloxane (HMDSO) in a radio-frequency (RF) plasma environment are allowed to diffuse into the microcavities of polydimethylsiloxane (PDMS), where surface reactions lead to the formation of an effective, glass-like thin-film barrier. Reactive species including silicon radicals and elemental oxygen maintain their reactivity for sufficient times (up to 7000 s) and survive the random diffusional walk through the microcavities to form glass barriers as much as 65 mm from the cavity entrance. The barrier thickness and the growth length can be controlled by the reaction time and chamber operating pressure. Increasing the cross sectional area of the cavity inlet and/or decreasing the mean free path was found to increase the thickness of the barrier film. Optical emission spectroscopic analysis was used to characterize the reactive fragments formed from HMDSO, and energy-dispersive X-ray analysis revealed that the barrier composition is consistent with oxides of silicon (SiO(x)). Formed inside PDMS microcavities, the glass barrier blocks the penetration or absorption of small molecules such as rhodamine B (RhB) and biotin, and also resists permeation of organic solvents such as toluene, preventing the PDMS microfluidic structures from swelling and deforming. Moreover, formation of glass-like thin films in PDMS microcavities enhances the stability of electroosmotic flow (EOF) relative to uncoated PDMS devices, in which EOF instabilities are significant; this enables separation by electrophoresis with reproducibility (relative standard deviation 3%, n = 5) and baseline peak resolution (R:1.3) comparable to that obtained in conventional fused-silica capillaries.
Authors:
Asif Riaz; Ram P Gandhiraman; Ivan K Dimov; Lourdes Basabe-Desmonts; Jens Ducrée; Stephen Daniels; Antonio J Ricco; Luke P Lee
Related Documents :
16104797 - Identification of characteristic aroma-active compounds from water dropwort (oenanthe j...
16688337 - Nitrobenzoxadiazoles and related heterocycles: a relationship between aromaticity, supe...
21229177 - Sonochemical polymerization of miniemulsions in organic liquids/water mixtures.
17824917 - Performance evaluation of the z2 coulter counter for wbc and rbc counting.
17297927 - Infrared temperature control system for a completely noncontact polymerase chain reacti...
22153307 - Effects of indomethacin and propranolol on chironomus riparius and physella (costatella...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-3
Journal Detail:
Title:  Lab on a chip     Volume:  -     ISSN:  1473-0189     ISO Abbreviation:  Lab Chip     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-3     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101128948     Medline TA:  Lab Chip     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Biomedical Diagnostics Institute, National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Intrinsic crystal phase separation in the antiferromagnetic superconductor Rb(y)Fe(2-x)Se(2): a diff...
Next Document:  The hyperglycemia stimulated myocardial endoplasmic reticulum (ER) stress contributes to diabetic ca...