Document Detail


Radiological and micro-computed tomography analysis of the bone at dental implants inserted 2, 3 and 4 mm apart in a minipig model with platform switching incorporated.
MedLine Citation:
PMID:  23020736     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: The purpose of this study was to assess the effect of inter-implant distance on interproximal bone utilizing platform switching. Analysis of interproximal bone usually depends on traditional two-dimensional radiographic assessment. Although there has been increased reliability of current techniques, there has been an inability to track bone level changes over time and in three dimensions. Micro-CT has provided three-dimensional imaging that can be used in conjunction with traditional two-dimensional radiographic techniques. METHODS: This study was performed on 24 female minipigs. Twelve animals received three implants with an inter-implant distance of 3 mm on one side of the mandible and another three implants on the contra-lateral side, where the implants were placed 2 mm apart creating a split mouth design. Twelve other animals received three implants with an inter-implant distance of 3 mm on one side of the mandible and another three implants on the contra-lateral side, where the implants were placed 4 mm apart creating a split mouth design too. The quantitative evaluation was performed comparatively on radiographs taken at t 0 (immediately after implantation) and at t 8 weeks (after termination). The samples were scanned by micro-computed tomography (μCT) to quantify the first bone to implant contact (fBIC) and bone volume/total volume (BV/TV). Mixed model regressions using the nonparametric Brunner-Langer method were used to determine the effect of inter-implant distance on the measured outcomes. RESULTS: The change in bone level was determined using radiography and its mean was 0.05 mm for an inter-implant distance of 3 and 0.00 mm for a 2 mm distance (P = 0.7268). The mean of this outcome was 0.18 mm for the 3 mm and for 4 mm inter-implant distance (P = 0.9500). Micro-computed tomography showed that the fBIC was always located above the reference, 0.27 and 0.20 mm for the comparison of 2-3 mm (P = 0.4622) and 0.49 and 0.34 mm for the inter-implant distance of 3 and 4 mm (P = 0.1699). BV/TV inside the defined parallelepipedic masks reached 82.38% for the 2 mm inter-implant distance and 85.00% for 3 mm, P = 0.8432. For the comparison of the 3-4 mm inter-implant distance, the means were 84.69% and 84.38%, respectively, P = 0.8401. Non-inferiority tests for the smaller inter-implant distances for both comparisons showed similar differences and similar tolerance ranges. CONCLUSION: The effect of a smaller interproximal distances between implants on bone level, fBIC and BV/TV assessed by two convergent investigation methods, radiology and μCT, was similar to that of larger distances. Implants can potentially be placed 2 mm apart instead of 3 mm and 3 mm apart instead of 4 mm when platform switching is utilized. Further research with a conventional platform is warranted.
Authors:
Nicolas Elian; Mitchell Bloom; Michel Dard; Sang-Choon Cho; Richard D Trushkowsky; Dennis Tarnow
Related Documents :
20494746 - Complications of small joint arthroplasty.
23701676 - Effects of directly autotransplanted tibial bone marrow aspirates on bone regeneration ...
24011496 - A 6-year prospective evaluation of a one-step hema-free self-etching adhesive in class ...
12690846 - Metacarpophalangeal joint arthroplasty in rheumatoid arthritis.
20494746 - Complications of small joint arthroplasty.
21357826 - Intracardiac electrogram t-wave alternans/variability increases before spontaneous vent...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-1
Journal Detail:
Title:  Clinical oral implants research     Volume:  -     ISSN:  1600-0501     ISO Abbreviation:  Clin Oral Implants Res     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-1     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9105713     Medline TA:  Clin Oral Implants Res     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
© 2012 John Wiley & Sons A/S.
Affiliation:
Department of Periodontology and Implant Dentistry, New York University College of Dentistry, New York, NY, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Cell death pathways in directly irradiated cells and cells exposed to medium from irradiated cells.
Next Document:  Leidenfrost point reduction on micro-patterned metallic surfaces.