Document Detail

Radiofrequency ablation of an atrial tachycardia emanating from the non-coronary aortic Cusp guided by an electroanatomic navigation system.
Jump to Full Text
MedLine Citation:
PMID:  20126596     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
We report on an atrial tachycardia (AT), emanating from the non-coronary (NC) aortic cusp, ablated with the aid of an electro-anatomical navigation system. In this setting, the electrocardiographic, electrophysiologic (EP), anatomical, and ablative considerations are discussed.Although NC aortic cusp focal ATs are an uncommon EP finding, their ablation is effective and safe, especially from an atrio-ventricular (AV) conductive point of view. This origin of AT must be invoked and systematically disclosed when a peri-AV nodal AT origin is suspected, in order to avoid a potentially harmful energy application at the vicinity of the AV conductive tissue.
Authors:
Agustin Bortone; Eric Maupas
Related Documents :
9448676 - Reentrant tachycardias. a look at where treatment stands today.
16839626 - Evaluation of post-radiofrequency myocardial injury by measuring cardiac troponin i lev...
3128586 - "nodoventricular" accessory pathway: evidence for a distinct accessory atrioventricular...
18817686 - Ventricular arrhythmia onset during diagnostic coronary angiography with a 5f or 4f uni...
7850836 - Wiktor coronary stent.
1290176 - Extracorporeal membrane oxygenation (ecmo) for neonatal respiratory failure.
Publication Detail:
Type:  Journal Article     Date:  2010-02-01
Journal Detail:
Title:  Indian pacing and electrophysiology journal     Volume:  10     ISSN:  0972-6292     ISO Abbreviation:  Indian Pacing Electrophysiol J     Publication Date:  2010  
Date Detail:
Created Date:  2010-02-03     Completed Date:  2010-05-20     Revised Date:  2010-09-27    
Medline Journal Info:
Nlm Unique ID:  101157207     Medline TA:  Indian Pacing Electrophysiol J     Country:  India    
Other Details:
Languages:  eng     Pagination:  99-103     Citation Subset:  -    
Affiliation:
Departement de Rythmologie. Hopital Prive Les Franciscaines. Unite de Cardiologie. 9, Impasse Jean Bouin. Nimes, France. agubene@hotmail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): Indian Pacing Electrophysiol J
Journal ID (publisher-id): Indian Pacing Electrophysiol J
ISSN: 0972-6292
Publisher: Indian Heart Rhythm Society
Article Information
Download PDF
Copyright: ? 2009 Bortone et al.
open-access:
collection publication date: Year: 2010
Electronic publication date: Day: 01 Month: 2 Year: 2010
Volume: 10 Issue: 2
First Page: 99 Last Page: 103
ID: 2811209
PubMed Id: 20126596
Publisher Id: ipej100099-00

Radiofrequency Ablation of an Atrial Tachycardia Emanating From the Non-coronary Aortic Cusp Guided by an Electroanatomic Navigation System
Agustin Bortone, MD
Eric Maupas, MD
Departement de Rythmologie. Hopital Prive Les Franciscaines. Unite de Cardiologie. 9, Impasse Jean Bouin. Nimes, France.
Correspondence: Address for correspondence: Dr Agust?n Bortone, M.D. Departement de Rythmologie. Hopital Prive Les Franciscaines. Unite de Cardiologie. 9, Impasse Jean Bouin. N?mes, France. E-mail: agubene@hotmail.com

Case Presentation

A 37 year-old woman, without any structural heart disease, was referred to our institution for management of symptomatic supra-ventricular tachycardia. Three anti-arrhythmic drugs had failed before the patient was considered for catheter ablation. Baseline 12-lead electrocardiogram (ECG) and echocardiogram were both normal. After written informed consent was obtained, an EP study was undertaken. A narrow complex tachycardia was easily induced by simple catheter manipulation (Figure 1). Upon cessation of ventricular pacing with capture at 20 ms faster than the tachycardia cycle length a V-A-A-V response was observed, which assessed the diagnosis of AT. Right atrium (RA) and coronary sinus (CS) activation maps were constructed using Carto? (Biosense Webster, Diamond Bar, CA.). The earliest activation region was located at the initial portion of the bundle of His. Afterwards, left atrium (LA) mapping was performed after transseptal access was obtained. No activation maps of the LA and the pulmonary veins were built because mapping was poor in terms of precocity. After retrograde aortic approach was performed, a NC aortic cusp activation map was created and exhibited the maximal precocity (Figure 2-panel A and Figure 3). A 10 seconds RF application at the NC aortic cusp site (25 W, 48?C, 30 cc/min) abolished the AT (Figure 2-panel B) and rendered this one no more inducible with and without isoproterenol administration. Prior to RF application, right and left coronary angiograms demonstrated that the ablation catheter was located at a safe distance with respect to the origin of the coronary arteries (Figure 4). There were no complications. During the one-year follow-up period the patient had an ECG Holter monitoring at months 1, 3, 6 and 12, and was invited to come to the ablation center in case of symptoms suggestive of AT recurrence. During all that period, the patient has been arrhythmia free without any anti-arrhythmic medication.


Discussion

It has been shown that the right and left aortic coronary cusps can give rise to ventricular tachycardia [1,2] while the NC aortic cusp can be a source of AT [2-6]. Although ATs emerging from the NC aortic cusp are uncommon; the safety of their ablation in terms of AV conduction disturbances, aortic leaflets integrity and embolic events has been assessed [2-4].

On the other hand, the fact that the interatrial septum and the NC aortic cusp are immediately adjacent [5], led some investigators to postulate that some aborted AT ablations presumed to emerge from the peri-AV nodal region could have been in fact related to a NC aortic cusp origin [2]. Accordingly, it seems reasonable to map the NC aortic cusp after mapping the left aspect of the interatrial septum and the initial portion of the CS when an AT, presumably emerging from the peri-AV nodal region, is diagnosed [2]. Furthermore, RF application at the right aspect of the interatrial septum while targeting peri-AV nodal ATs carries a substantial risk of complete heart block, while RF application to the NC aortic cusp, is less dangerous; unless the RF is applied near the commissure with the right coronary cusp because at that location, the fast-pathway can be injured [5].

When mapping the posterior and left-sided aspects of the NC aortic cusp, large atrial electrograms must be recorded whereas, when the catheter approaches the commissure with the right coronary cusp, His bundle electrograms and large ventricular electrograms appear. Although, atrial NC aortic cusp atrial electrograms have been described as fractionated [5,7] in our case they were not fractionated (Figure 3), suggesting an abnormal automaticity mechanism (as assessed by the impossibility to entrain the AT and its spontaneous cycle length variations) or a supra-valvular myocardium origin. These assertions remain however, speculative.

Typically, NC aortic cusp focal AT 12-lead ECG shows positive P waves in V1, while an anterior tricuspid valve origin or/and a RA appendage origin, both exhibit a negative P wave pattern in V1 [4]. Interestingly, in our case the ECG shows a positive/negative P wave in V1 (Figure 1) which can correspond to an anatomical variation of the AT origin within the space between the NC aortic cusp and the interatrial septum or a variation of the patient's anatomy.

Regarding the energy used for NC cusp ablation, recent publications, either experimental or clinical, have assessed the security of standard RF energy, cooled-tip RF energy and cryothermal ablation [1-8]. In our case, we have chosen irrigated RF energy only because the available catheter in our EP laboratory, at the moment of the procedure, compatible with the Carto? system was irrigated. However, standard RF ablation and cryothermal ablation may be sufficient.

Concerning electroanatomical navigation systems, although non-indispensable, they can depict comfortably the activation of all the chambers mapped and allow the reproducible repositioning of the ablation catheter at the "spot of interest". These systems have therefore the potential to render easer the ablation procedures. Moreover, merging the computed tomography of the heart with the electro-anatomic reconstruction may add further information, enhance the understanding of the complex anatomic relationship between structures, and increase safety at the level of coronary cusps [9,10].

Finally, the distance between the ablation catheter and the origin of the coronary arteries should be absolutely disclosed by means of a prior coronary angiogram, in order to avoid a serious coronary complication [2].


Conclusion

Although ATs originating from the NC aortic cusp are uncommon, their ablation is feasible and safe. NC aortic cusp ATs must be invoked and systematically disclosed when a peri-AV nodal AT origin is suspected, in order to avoid a potentially harmful energy application at the vicinity of the AV conductive tissue.


References
Ouyang F,et al. Repetitive monomorphic ventricular tachycardia originating from the aortic sinus cusp: electrocardiographic characterization for guiding catheter ablationJ Am Coll CardiolYear: 20023950011823089
Rillig A,et al. Catheter ablation within the sinus of Valsalva-a safe effective approach for treatment of atrial and ventricular tachycardiasHeart RhythmYear: 20085126518774100
Ouyang F,et al. Focal atrial tachycardia originating from the non-coronary aortic sinus: electrophysiological characteristics and catheter ablationJ Am Coll CardiolYear: 20064812216814658
Das S,et al. Catheter ablation of peri-AV nodal atrial tachycardia from the noncoronary cusp of the aortic valveJ Cardiovasc ElectrophysiolYear: 20081923118031512
Suleiman M,et al. Ablation above the semilunar valves: when, why, and how? Part IIHeart RhythmYear: 20085162518984543
Kriatselis C,et al. Ectopic atrial tachycardias with early activation at His site: radiofrequency ablation through a retrograde approachEuropace Year: 20081069818403384
Yamada T,et al. Atrial tachycardia originating from the noncoronary aortic cusp and musculature connection with the atria: relevance for catheter ablationHeart RhythmYear: 20063149417161795
d'Avila A,et al. What is the most appropriate energy source for aortic cusp ablation? A comparison of standard RF, cooled-tip RF and cryothermal ablationJ Interv Card ElectrophysiolYear: 2006163117029021
Pasquie JL,et al. Image-guided ablation of a ventricular tachycardia originating from the left aortic cuspJ Cardiovasc ElectrophysiolYear: 200617103216948750
Bortone A,et al. Dual tachycardias associating double-exit left aortic sinus cusp tachycardia with paroxysmal atrial fibrillation: evidence of a link between both arrhythmias by means of the autonomic nervous systemJ Cardiovasc ElectrophysiolYear: 200718133417655674

Article Categories:
  • Case Report

Keywords: Atrial tachycardia, non-coronary aortic cusp, radiofrequency ablation, Carto.

Previous Document:  Second Degree Heart Block Associated with QT Prolongation.
Next Document:  Ganglionic plexus ablation during pulmonary vein isolation - predisposing to ventricular arrhythmias...