Document Detail


Radial force measurements in carotid stents: influence of stent design and length of the lesion.
MedLine Citation:
PMID:  21514520     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
PURPOSE: To assess the differences in radial force of carotid stents and whether the length of the lesion influences the measurements.
MATERIALS AND METHODS: Different models of tapered stents of similar size (length, 30 mm) were used. The tapered nitinol Acculink, Protégé, and Cristallo Ideale carotid artery stents and the straight, braided Elgiloy carotid Wallstent were compared. A measurement device consisting of three film loops along the stent body connected to aluminium rods with copper strain gauges was developed. Five stents of each type were deployed within 3-mm stenoses in simulated long (26 mm) and short (8 mm) stenoses.
RESULTS: In the short stenosis simulation, the greatest radial force was seen in the Protégé stent, at 3.14 N ± 0.45, followed by the Cristallo Ideale stent (1.73 N ± 0.51), Acculink (1.16 N ± 0.21), and Wallstent (0.84 N ± 0.10; P < .001). In the long stenosis simulation, peak radial force again was highest in the Protégé stent (1.67 N ± 0.37), but the Acculink stent was second (0.95 N ± 0.12) and the Wallstent third (0.80 N ± 0.06). The Cristallo Ideale stent, in contrast to the short stenosis simulation, produced the least radial force (0.44 N ± 0.13) in the long stenosis simulation (P = .001).
CONCLUSIONS: Radial forces exerted by carotid stents vary significantly among stent designs. Differences between stent types are dependent on the length of the stenosis. An understanding of radial force is necessary for a well-considered choice of stent type in each individual patient.
Authors:
Michiel T Voûte; Johanna M Hendriks; Jorinde H H van Laanen; Peter M T Pattynama; Bart E Muhs; Don Poldermans; Hence J M Verhagen
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of vascular and interventional radiology : JVIR     Volume:  22     ISSN:  1535-7732     ISO Abbreviation:  J Vasc Interv Radiol     Publication Date:  2011 May 
Date Detail:
Created Date:  2011-04-25     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9203369     Medline TA:  J Vasc Interv Radiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  661-6     Citation Subset:  IM    
Copyright Information:
Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Affiliation:
Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Temporary balloon tamponade for managing subclavian arterial injury by inadvertent central venous ca...
Next Document:  A Novel Image-guided Balloon Vaginoplasty Method to Treat Obstructive Vaginal Anomalies.