Document Detail


Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease: Cutoff Values and Diagnostic Accuracy of Quantitative [(15)O]H2O PET Imaging.
MedLine Citation:
PMID:  25277618     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
BACKGROUND: Recent studies have demonstrated improved diagnostic accuracy for detecting coronary artery disease (CAD) when myocardial blood flow (MBF) is quantified in absolute terms, but there are no uniformly accepted cutoff values for hemodynamically significant CAD.
OBJECTIVES: The goal of this study was to determine cutoff values for absolute MBF and to evaluate the diagnostic accuracy of quantitative [(15)O]H2O positron emission tomography (PET).
METHODS: A total of 330 patients underwent both quantitative [(15)O]H2O PET imaging and invasive coronary angiography in conjunction with fractional flow reserve measurements. A stenosis >90% and/or fractional flow reserve ≤0.80 was considered obstructive; a stenosis <30% and/or fractional flow reserve >0.80 was nonobstructive.
RESULTS: Hemodynamically significant CAD was diagnosed in 116 (41%) of 281 patients who fulfilled study criteria for CAD. Resting perfusion was 1.00 ± 0.25 and 0.92 ± 0.23 ml/min/g in regions supplied by nonstenotic and significantly stenosed vessels, respectively (p < 0.001). During stress, perfusion increased to 3.26 ± 1.04 ml/min/g and 1.73 ± 0.67 ml/min/g, respectively (p < 0.001). The optimal cutoff values were 2.3 and 2.5 for hyperemic MBF and myocardial flow reserve, respectively. For MBF, these cutoff values showed a sensitivity, specificity, and accuracy for detecting significant CAD of 89%, 84%, and 86%, respectively, at a per-patient level and 87%, 85%, and 85% at a per-vessel level. The corresponding myocardial flow reserve values were 86%, 72%, and 78% (per patient) and 80%, 82%, and 81% (per vessel). Age and sex significantly affected diagnostic accuracy of quantitative PET.
CONCLUSIONS: Quantitative MBF measurements with the use of [(15)O]H2O PET provided high diagnostic performance, but both sex and age should be taken into account.
Authors:
Ibrahim Danad; Valtteri Uusitalo; Tanja Kero; Antti Saraste; Pieter G Raijmakers; Adriaan A Lammertsma; Martijn W Heymans; Sami A Kajander; Mikko Pietilä; Stefan James; Jens Sörensen; Paul Knaapen; Juhani Knuuti
Related Documents :
10466478 - Pharmacologic agents on cardiovascular mass, coronary dynamics and collagen in aged spo...
19653918 - Protective effects of hydroalcoholic extract from rhizomes of cynodon dactylon (l.) per...
4039668 - Pharmacological interventions and myocardial infarct size in rat.
20729398 - Altered in vivo left ventricular torsion and principal strains in hypothyroid rats.
3089948 - The use of impedance cardiography in heart failure.
20227258 - Plasma carotenoids and risk of acute myocardial infarction in the singapore chinese hea...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of the American College of Cardiology     Volume:  64     ISSN:  1558-3597     ISO Abbreviation:  J. Am. Coll. Cardiol.     Publication Date:  2014 Oct 
Date Detail:
Created Date:  2014-10-03     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8301365     Medline TA:  J Am Coll Cardiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1464-75     Citation Subset:  AIM; IM    
Copyright Information:
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Fasting levels of high-sensitivity growth hormone predict cardiovascular morbidity and mortality: ...
Next Document:  Integrated solid phase extraction - capillary liquid chromatography (speLC) interfaced to ESI-MS/MS ...