The goal of this study was to use a pressure sensor to measure the force distribution and contact area of the hand when gripping, pushing, and pulling a cylinder. Data was collected from 10 subjects with no hand impairments and from 1 subject with rheumatoid arthritis (RA). Subjects grasped an aluminum cylinder wrapped with a Tekscan pressure sensor and performed each trial at 25%, 50%, and 100% maximum voluntary exertion. A relationship was found between increasing exertion and increasing hand area with increasing hand contact area. The force distribution maps showed the thenar region of the hand exerts the most force during pushing while the metacarpal joint line exerts the highest force during pulling. The third and fourth phalange were found to exert the highest phalange force during gripping. The force distribution maps from the RA subject showed higher thumb forces and distal phalange forces, relative to the entire phalange, compared to the non-impaired subjects. This suggests that the RA subject compensates for the lack of phalange function with the regions of the hand that still function. Future studies should sample individuals with a larger hand area range and sample more individuals with RA.
Authors:
Jon W Nicholas; Russel J Corvese; Charles Woolley; Thomas J Armstrong
Related Documents :
3566469 - Electron microscope study of osteoclasts with special reference to the three-dimensiona...
1449759 - The roles of handedness and stimulus asymmetry in aesthetic preference.
20877849 - Mechanism of visible-light photoisomerization of a rhenium(i) carbonyl-diimine complex.
1509649 - Bovine spongiform encephalopathy: aspects of the clinical picture and analyses of possi...
22415119 - Forced to be right.
21255499 - Symmetrical high frequency oscillation increases artificial mucus flow without changing...
21077719 - Perceptual grouping affects pitch judgments across time and frequency.
22255829 - Laboratory in a box: wearable sensors and its advantages for gait analysis.
1380339 - Circadian rhythms in glutathione and glutathione-s transferase activity of rat liver.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Work (Reading, Mass.)     Volume:  41     ISSN:  1875-9270     ISO Abbreviation:  Work     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-02-09     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204382     Medline TA:  Work     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  605-12     Citation Subset:  IM    
Affiliation:
Biomedical Engineering, University of Michigan, 2200 Bonisteel Blvd., Ann Arbor, MI 48109-2099, United States.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The manual transport of load and the commercial aviation in Brazil.
Next Document:  Human activity reference database.