Quantification aspects of constant pressure (ultra) high pressure liquid chromatography using mass-sensitive detectors with a nebulizing interface.
MedLine Citation:
PMID:  23274072     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The present contribution investigates the quantitation aspects of mass-sensitive detectors with nebulizing interface (ESI-MSD, ELSD, CAD) in the constant pressure gradient elution mode. In this operation mode, the pressure is controlled and maintained at a set value and the liquid flow rate will vary according to the inverse mobile phase viscosity. As the pressure is continuously kept at the allowable maximum during the entire gradient run, the average liquid flow rate is higher compared to that in the conventional constant flow rate operation mode, thus shortening the analysis time. The following three mass-sensitive detectors were investigated: mass spectrometry detector (MS), evaporative light scattering detector (ELSD) and charged aerosol detector (CAD) and a wide variety of samples (phenones, polyaromatic hydrocarbons, wine, cocoa butter) has been considered. It was found that the nebulizing efficiency of the LC-interfaces of the three detectors under consideration changes with the increasing liquid flow rate. For the MS, the increasing flow rate leads to a lower peak area whereas for the ELSD the peak area increases compared to the constant flow rate mode. The peak area obtained with a CAD is rather insensitive to the liquid flow rate. The reproducibility of the peak area remains similar in both modes, although variation in system permeability compromises the 'long-term' reproducibility. This problem can however be overcome by running a flow rate program with an optimized flow rate and composition profile obtained from the constant pressure mode. In this case, the quantification remains reproducibile, despite any occuring variations of the system permeability. Furthermore, the same fragmentation pattern (MS) has been found in the constant pressure mode compared to the customary constant flow rate mode.
Authors:
M Verstraeten; K Broeckhoven; F Lynen; K Choikhet; K Landt; M Dittmann; K Witt; P Sandra; G Desmet
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-12-16
Journal Detail:
Title:  Journal of chromatography. A     Volume:  -     ISSN:  1873-3778     ISO Abbreviation:  J Chromatogr A     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-31     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9318488     Medline TA:  J Chromatogr A     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Elsevier B.V. All rights reserved.
Affiliation:
Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS-IR), Pleinlaan 2, 1050 Brussels, Belgium.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radioisotope post-labeling upconversion nanophosphors for in vivo quantitative tracking.
Next Document:  Ultra-high pressure liquid chromatography-mass spectrometry for plant metabolomics: A systematic com...